National foreword
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General principles for the application of surge arresters
5 Surge arrester fundamentals and applications issues
6 Insulation coordination and surge arrester applications
7 Surge arresters for special applications
8 Asset management of surge arresters
Annex A (informative) - Determination of temporary
overvoltages due to earth faults
Annex B (informative) - Current practice
Annex C (informative) - Arrester modelling techniques
for studies involving insulation coordination and
energy requirements
Annex D (informative) - Diagnostic indicators of
metal-oxide surge arresters in service
Annex E (informative) - Typical data needed from
arrester manufacturers for proper selection
of surge arresters
Annex F (informative) - Typical maximum residual voltages
for metal-oxide arresters without gaps according
to IEC 60099-4
Annex G (informative) - Steepness reduction of incoming
surge with additional line terminal surge capacitance
Annex H (informative) - Comparison of the former energy
classification system based on line discharge classes
and the present classification system based on thermal
energy ratings for operating duty tests and repetitive
charge transfer ratings for repetitive single
event energies
Annex I (informative) - Estimation of arrester cumulative
charges and energies during line switching
Annex J (informative) - End of life and replacement of old
gapped SiC-arresters
Bibliography
Annex ZA (normative) -Normative references to
international publications with their
corresponding European publications
Gives information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV.
DevelopmentNote |
Supersedes I.S. EN 60099-5. (04/2018)
|
DocumentType |
Standard
|
Pages |
0
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
IEC 60099-5:2013 | Identical |
EN IEC 60099-5:2018 | Identical |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC TR 60071-4:2004 | Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks |
EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC TR 62271-300:2006 | High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60099-6:2002 | Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less |
EN 60507:2014 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60099-8:2017 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.