I.S. EN ISO 5167-1:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

MEASUREMENT OF FLUID FLOW BY MEANS OF PRESSURE DIFFERENTIAL DEVICES INSERTED IN CIRCULAR CROSS-SECTION CONDUITS RUNNING FULL - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS

Available format(s)

Hardcopy , PDF

Superseded date

04-03-2023

Superseded by

I.S. EN ISO 5167-1:2022

Language(s)

English

Published date

01-01-2003

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€76.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and subscripts
  4.1 Symbols
  4.2 Subscripts
5 Principle of the method of measurement and computation
  5.1 Principle of the method of measurement
  5.2 Method of determination of the diameter ratio of
      the selected standard primary device
  5.3 Computation of flowrate
  5.4 Determination of density, pressure and temperature
6 General requirements for the measurements
  6.1 Primary device
  6.2 Nature of the fluid
  6.3 Flow conditions
7 Installation requirements
  7.1 General
  7.2 Minimum upstream and downstream straight lengths
  7.3 General requirement for flow conditions at the primary device
  7.4 Flow conditioners (see also Annex C)
8 Uncertainties on the measurement of flowrate
  8.1 Definition of uncertainty
  8.2 Practical computation of the uncertainty
Annex A (informative) - Iterative computations
Annex B (informative) - Examples of values of the pipe wall
                        uniform equivalent roughness, k
Annex C (informative) - Flow conditioners and flow straighteners
Bibliography

Covers the geometry and method of use (installation and operating conditions) of orifice plates, nozzles and Venturi tubes when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit. Also gives necessary information for calculating the flow-rate and its associated uncertainty.

DocumentType
Standard
Pages
44
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy
Supersedes

ISO 5167-3:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 3: Nozzles and Venturi nozzles
ISO 5167-4:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes
ISO/TR 5168:1998 Measurement of fluid flow Evaluation of uncertainties
ISO 5167-2:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates
ISO/TR 3313:1998 Measurement of fluid flow in closed conduits Guidelines on the effects of flow pulsations on flow-measurement instruments
ISO/TR 9464:2008 Guidelines for the use of ISO 5167:2003
ISO 4006:1991 Measurement of fluid flow in closed conduits — Vocabulary and symbols

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.