I.S. EN ISO 5167-1:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEASUREMENT OF FLUID FLOW BY MEANS OF PRESSURE DIFFERENTIAL DEVICES INSERTED IN CIRCULAR CROSS-SECTION CONDUITS RUNNING FULL - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
Hardcopy , PDF
04-03-2023
English
01-01-2003
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and subscripts
4.1 Symbols
4.2 Subscripts
5 Principle of the method of measurement and computation
5.1 Principle of the method of measurement
5.2 Method of determination of the diameter ratio of
the selected standard primary device
5.3 Computation of flowrate
5.4 Determination of density, pressure and temperature
6 General requirements for the measurements
6.1 Primary device
6.2 Nature of the fluid
6.3 Flow conditions
7 Installation requirements
7.1 General
7.2 Minimum upstream and downstream straight lengths
7.3 General requirement for flow conditions at the primary device
7.4 Flow conditioners (see also Annex C)
8 Uncertainties on the measurement of flowrate
8.1 Definition of uncertainty
8.2 Practical computation of the uncertainty
Annex A (informative) - Iterative computations
Annex B (informative) - Examples of values of the pipe wall
uniform equivalent roughness, k
Annex C (informative) - Flow conditioners and flow straighteners
Bibliography
Covers the geometry and method of use (installation and operating conditions) of orifice plates, nozzles and Venturi tubes when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit. Also gives necessary information for calculating the flow-rate and its associated uncertainty.
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ONORM EN ISO 5167-1 : 2003 | Identical |
UNE-EN ISO 5167-1:2003 | Identical |
SN EN ISO 5167-1 : 2003 | Identical |
NF EN ISO 5167-1 : 2003 | Identical |
ISO 5167-1:2003 | Identical |
NEN EN ISO 5167-1 : 2003 | Identical |
EN ISO 5167-1:2003 | Identical |
UNI EN ISO 5167-1 : 2004 | Identical |
NBN EN ISO 5167-1 : 2003 | Identical |
BS EN ISO 5167-1:2003 | Identical |
DIN EN ISO 5167-1:2004-01 | Identical |
NS EN ISO 5167-1 : 2ED 2003 | Identical |
ISO 5167-3:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 3: Nozzles and Venturi nozzles |
ISO 5167-4:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes |
ISO/TR 5168:1998 | Measurement of fluid flow Evaluation of uncertainties |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
ISO/TR 3313:1998 | Measurement of fluid flow in closed conduits Guidelines on the effects of flow pulsations on flow-measurement instruments |
ISO/TR 9464:2008 | Guidelines for the use of ISO 5167:2003 |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.