• I.S. EN ISO 52016-1:2017

    Current The latest, up-to-date edition.

    ENERGY PERFORMANCE OF BUILDINGS - ENERGY NEEDS FOR HEATING AND COOLING, INTERNAL TEMPERATURES AND SENSIBLE AND LATENT HEAT LOADS - PART 1: CALCULATION PROCEDURES (ISO 52016-1:2017)

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  06-08-2017

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    European foreword
    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols, subscripts and abbreviations
    5 Description of the methods
    6 Calculation method
    7 Quality control
    8 Compliance check
    Annex A (normative) - Input and method selection data
            sheet - Template
    Annex B (informative) - Input and method selection data
            sheet - Default choices
    Annex C (normative) - Regional references in line with
            ISO Global Relevance Policy
    Annex D (normative) - Multi-zone calculation with thermal
            coupling between zones
    Annex E (normative) - Heat transfer and solar heat gains
            of windows and special elements
    Annex F (normative) - Calculation of solar shading
            reduction factors
    Annex G (normative) - Dynamic transparent building elements
    Bibliography

    Abstract - (Show below) - (Hide below)

    This document specifies calculation methods for the assessment of: a) the (sensible) energy need for heating and cooling, based on hourly or monthly calculations; b) the latent energy need for (de-)humidification, based on hourly or monthly calculations; c) the internal temperature, based on hourly calculations; d) the sensible heating and cooling load, based on hourly calculations; e) the moisture and latent heat load for (de-)humidification, based on hourly calculations; f) the design sensible heating or cooling load and design latent heat load using an hourly calculation interval; g) the conditions of the supply air to provide the necessary humidification and dehumidification.

    General Product Information - (Show below) - (Hide below)

    Committee TC 163
    Development Note Supersedes I.S. EN ISO 13792, I.S. EN ISO 13791, I.S. EN ISO 13790, I.S. EN 15265 and I.S. EN 15255. (12/2017)
    Document Type Standard
    Product Note The date of any NSAI previous adoption may not match the date of its original CEN/CENELEC document
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 13789:2017 Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method
    CEN/TS 16629:2014 Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards
    ISO 13792:2012 Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling Simplified methods
    EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
    CEN/TS 16628:2014 Energy Performance of Buildings - Basic Principles for the set of EPB standards
    ISO 9488:1999 Solar energy Vocabulary
    EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
    ISO 52022-3:2017 Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing
    ISO 15927-4:2005 Hygrothermal performance of buildings — Calculation and presentation of climatic data — Part 4: Hourly data for assessing the annual energy use for heating and cooling
    ISO 15099:2003 Thermal performance of windows, doors and shading devices — Detailed calculations
    EN 15265:2007 Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures
    ISO 52000-1:2017 Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures
    ISO 52017-1:2017 Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures
    ISO 15927-5:2004 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 5: Data for design heat load for space heating
    ISO 52010-1:2017 Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations
    ISO/TR 52016-2:2017 Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
    ISO/TR 52019-2:2017 Energy performance of buildings Hygrothermal performance of building components and building elements Part 2: Explanation and justification
    ISO 9050:2003 Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
    EN 12831-1:2017 Energy performance of buildings - Method for calculation of the design heat load - Part 1: Space heating load, Module M3-3
    ISO 13786:2017 Thermal performance of building components — Dynamic thermal characteristics — Calculation methods
    ISO 13370:2017 Thermal performance of buildings — Heat transfer via the ground — Calculation methods
    ISO/TR 52000-2:2017 Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1
    ISO 13791:2012 Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling General criteria and validation procedures
    EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
    ISO 15927-2:2009 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 2: Hourly data for design cooling load
    EN 15255:2007 Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures
    ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
    ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
    ISO 13790:2008 Energy performance of buildings Calculation of energy use for space heating and cooling
    ASHRAE 140 : 2014 METHOD OF TEST FOR THE EVALUATION OF BUILDING ENERGY ANALYSIS COMPUTER PROGRAMS
    ISO 7345:1987 Thermal insulation Physical quantities and definitions
    ISO 10292:1994 Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective