I.S. ENV 13730-2:2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
HEALTHCARE INFORMATICS - BLOOD TRANSFUSION RELATED MESSAGES - PART 2: PRODUCTION RELATED MESSAGES (BTR-PROD)
Hardcopy , PDF
13-05-2021
English
01-01-2002
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 SCOPE
2 NORMATIVE REFERENCES
3 TERMS, DEFINITIONS AND ABBREVIATIONS
4 REQUIREMENTS
4.1 GENERAL CONFORMANCE REQUIREMENTS
4.2 IMPLEMENTATION RECOMMENDATIONS
5 COMMUNICATION ROLES
5.1 GENERAL
5.1.1 Sending role requirements
5.1.2 Receiving role requirements
5.2 USE CASE DIAGRAM AND SCENARIOS (GENERAL USE CASE)
5.3 GROUP 2: MESSAGE SEQUENCES
5.3.1 Blood component production message domain
6 REQUIREMENTS AND GENERAL MESSAGE DESCRIPTIONS
6.1 CONFORMANCE REQUIREMENTS
6.2 GENERAL MESSAGE DESCRIPTIONS
6.3 BLOOD/BLOOD COMPONENT COLLECTION REQUEST MESSAGE
6.3.1 Scope of this message
6.3.2 Blood/blood component collection request message
6.4 BLOOD/BLOOD COMPONENT CLASSIFICATION REQUEST MESSAGE
6.4.1 Scope of this message
6.4.2 Blood/blood component classification request
message
6.5 BLOOD/BLOOD COMPONENT CLASSIFICATION REPORT MESSAGE
6.5.1 Scope of the message
6.5.2 Blood/blood component classification report
message
6.6 BLOOD/BLOOD COMPONENT COLLECTED DELIVER NOTE MESSAGE
6.6.1 Scope of this message
6.6.2 Blood/blood component collected delivery note
message
6.7 BLOOD COMPONENT REQUEST MESSAGE
6.7.1 Scope of this message
6.7.2 Blood component request message
6.8 BLOOD COMPONENT MANUFACTURED DELIVERY NOTE MESSAGE
6.8.1 Scope of this message
6.8.2 Blood component manufactured delivery note
message
6.9 BLOOD COMPONENT PROCESSING REQUEST MESSAGE
6.9.1 Scope of this message
6.9.2 Blood component processing request message
6.10 BLOOD COMPONENT PROCESSED DELIVERY NOTE MESSAGE
6.10.1 Scope of this message
6.10.2 Blood component processed delivery note
message
7 DOMAIN INFORMATION MODEL (DIM)
7.1 INTRODUCTION
7.1.1 The modelling approach
7.1.2 Presentation of attributes from generalisations
7.2 GENERAL MESSAGE SUBSYSTEM
Class Descriptions
7.2.1 requested item message
7.2.2 issued item message
7.2.3 blood/blood components collector
7.2.4 blood components manufacturer
7.2.5 blood components dispenser
7.2.6 blood components processor
7.3 SPECIFIC MESSAGE SUBSYSTEM
Class Descriptions
7.3.1 original message identification
7.3.2 blood/blood component collection request
message
7.3.3 blood/blood component classification request
message
7.3.4 blood/blood component classification report
message
7.3.5 blood/blood component collected delivery note
message
7.3.6 blood component request message
7.3.7 blood component manufactured delivery note
message
7.3.8 blood component processing request message
7.3.9 blood component processed delivery note message
7.4 COMMUNICATING PARTIES SUBSYSTEM
Class descriptions
7.4.1 message sender
7.4.2 message receiver
7.5 HEALTHCARE AGENT SUBSYSTEM
Class descriptions
7.5.1 healthcare agent in context
7.5.2 healthcare agent relationship
7.5.3 healthcare agent [3.30]
7.5.4 healthcare party [3.33]
7.5.5 healthcare organisation [3.32]
7.5.6 healthcare professional [3.34]
7.6 COLLECTED ITEM SUBSYSTEM
Class descriptions
7.6.1 collected item
7.6.2 blood component 13.91
7.7 REQUESTED ITEM
Class Descriptions
7.7.1 requested item
7.7.2 requested blood component information
7.7.3 delivery location
7.8 ISSUED ITEM SUBSYSTEM
Class Descriptions
7.8.1 issued blood component
7.8.2 blood component characteristic
7.8.3 blood component unit
7.8.4 quantity of blood component
7.8.5 issued blood component administrative details
7.8.6 issued blood component information
7.8.7 unit (container) characteristic
7.9 PAYMENT GUARANTOR SUBSYSTEM
Class Descriptions
7.9.1 payment details
7.9.2 payment guarantor
7.9.3 payment
7.10 LABORATORY INVESTIGATION SUBSYSTEM
7.10.1 laboratory investigation (ENV 16 13)
7.10.2 requested laboratory investigation (ENV 16 13)
7.10.3 laboratory investigation report (ENV 1613)
7.11 BLOOD DONOR SUBSYSTEM
Class Descriptions
7.11.1 blood donor [3.13]
7.11.2 clinical information [3.18]
7.11.3 clinical information item
7.12 COMMON SUBCLASSES
Class Descriptions
7.12.1 address
7.12.2 event date and time
7.12.3 general message information
7.12.4 identifier
7.12.5 language details
7.12.6 measurement
7.12.7 message identification
7.12.8 party identifier
7.12.9 person name details
7.12.10 structured address
7.12.11 structured person name
7.12.12 time interval
7.12.13 time period
7.12.14 unstructured address
7.12.15 unstructured name details
7.12.16 value of quantity
ANNEX A (INFORMATIVE) HOW TO READ THE MODELS
ANNEX B (INFORMATIVE) COMPOUND AND SIMPLE DATA TYPES
RATIONALE AND HOW TO USE THE DATA TYPES IN MESSAGES
ANNEX C (NORMATIVE) GUIDE TO USAGE OF CEN/TC 251/ENV 1613
INDEX
Describes general messages (3.41) for electronic information interchange between computer systems used by healthcare (3.29) parties (3.33) in the blood transfusion (3.16) domain.
DocumentType |
Standard
|
Pages |
113
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
ENV 13730-2:2002 | Identical |
ENV 1613 : 1995 | MEDICAL INFORMATICS - MESSAGES FOR EXCHANGE OF LABORATORY INFORMATION |
NFS 97 531 : 2010 | HEALTH INFORMATICS - BLOOD TRANSFUSION MESSAGES - DELIVERY MESSAGE FOR LABILE BLOOD PRODUCTS AND DELIVERY RETURN MESSAGE |
NFS 97 532 : 2010 | HEALTH INFORMATICS - BLOOD TRANSFUSION MESSAGES - DISTRIBUTION MESSAGE FOR LABILE BLOOD PRODUCTS |
ENV 12539 : 1997 | MEDICAL INFORMATICS - REQUEST AND REPORT MESSAGES FOR DIAGNOSTIC SERVICE DEPARTMENTS |
ISO 5281:1980 | Aromatic hydrocarbons — Benzene, xylene and toluene — Determination of density at 20 degrees C |
ISO/IEC 7826-1:1994 | Information technology General structure for the interchange of code values Part 1: Identification of coding schemes |
CR 12587:1996 | Medical Informatics - Methodology for the development of healthcare messages |
NFS 97 530 : 2010 | HEALTH INFORMATICS - BLOOD TRANSFUSION MESSAGES - COMMUNICATION AND DATA MODEL |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.