I.S. ENV 1998-3:1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
EUROCODE 8 - DESIGN PROVISIONS FOR EARTHQUAKE RESISTANCE OF STRUCTURES - PART 3: TOWERS, MASTS AND CHIMNEYS
Hardcopy , PDF
14-08-2005
English
01-01-1996
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
1 General
1.1 Scope
1.2 Definitions
1.3 Special terms used in Part 3 of Eurocode 8
1.4 Definitions
1.5 S.I. Units
1.6 Symbols
2 Basic requirement and compliance criteria
2.1 Scope
2.2 Compliance criteria
2.3 Importance factors
2.4 Non collapse requirement (ultimate limit state)
2.5 Minimisation of damage (serviceability limit state)
2.6 Behaviour factor
3 Seismic action
3.1 Definition of the seismic input
3.2 Elastic response spectrum
3.3 Design spectrum
3.4 Time-history representation
3.5 Long period components of the motion at a point
3.6 Spatial variability of the seismic motion
4 Modelling of structures
4.1 Number of degrees of freedom
4.2 Masses
4.3 Stiffnesses
4.4 Damping
4.5 Soil-structure interaction
5 Methods of analysis
5.1 Applicable methods
5.2 Simplified dynamic analysis
5.3 Multimodal analysis
5.4 Combination of different ground motion components
5.5 Combination of internal actions
5.6 Combination of the seismic action with other
actions
5.7 Displacements
6 Safety verification
6.1 Ultimate limit state
6.2 Serviceability limit state
Annexes
Annex A (Informative) Linear dynamic analysis accounting
for a rotational seismic motion
Annex B (Informative) Analysis procedure for damping
Annex C (Informative) Soil-structure interaction
Annex D (Informative) Number of degrees of freedom and
number of modes of vibration
Annex E (Informative) Special rules of reinforced
concrete chimneys
Annex F (Informative) Materials for steel structures
Annex G (Informative) Electric transmission towers
Gives requirements, criteria, and rules for the earthquake resistant design of tall slender structures: towers, including bell-towers and intake towers, masts, industrial chimneys and lighthouses.
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ENV 1998-3 : 1996 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.