I.S. ISO 5369:1987
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
BREATHING MACHINES FOR MEDICAL USE - LUNG VENTILATORS
Hardcopy , PDF
11-03-2003
English
01-09-1989
0 Introduction
1 Scope and field of application
2 References
Section one: Breathing machines - General
3 Classification and definitions of types of
breathing machines
Section two: Lung ventilators
4 Definitions related to the performance of lung
ventilators
5 Lung ventilator characteristics
6 Test lung and method for testing performance of
lung ventilators
7 Power sources
8 Accuracy of controls, indications and pressure-relief
valves
9 Spirometer and other devices for indication of
ventilator function
10 characteristics of delivered gas
11 Expiratory resistance
12 Internal compliance of apparatus
13 Fittings connecting the adult ventilator, patient
and the spirometer
14 Alarms
15 Humidifiers
16 Methods of cleaning, designation or sterilization
17 Electrical safety requirements
18 Information to be provided by the manufacturer
19 Marking
20 Bibliography
Annex A - Test methods
Annex B - Peak airway pressures developed by constant flow
generators in tests
Annex C - Respiratory data on normal children compiled from
available literature
Describes basic requirements for lung ventilators for medical use. Section one defines the main classes of breathing machines used in medical practice and indicates how these may be further subdivided according to their mode of action. Section two gives definitions of the terms used in the field of lung ventilators designed for adult, paediatric and neonatal patients.
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
ISO 5356-1:2015 | Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets |
ISO 5356-2:2012 | Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors |
ISO 8185:2007 | Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems |
IEC 60601-2-13:2003+AMD1:2006 CSV | Medical electrical equipment - Part 2-13: Particular requirements for the safety and essential performance of anaesthetic systems |
IEC 60601-2-12:2001 | Medical electrical equipment - Part 2-12: Particular requirements for the safety of lung ventilators - Critical care ventilators |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.