IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Instrument transformers - Part 1: Current transformers

Available format(s)

Hardcopy , PDF

Language(s)

English - French, English, French

Published date

13-02-2003

Superseded date

18-09-2012

€529.58
Excluding VAT
Summarise this standard

FOREWORD
1 General
   1.1 Scope
   1.2 Normative references
2 Definitions
   2.1 General definitions
   2.2 Additional definitions for measuring current
        transformers
   2.3 Additional definitions for protective current
        transformers
3 Normal and special service conditions
   3.1 Normal service conditions
   3.2 Special service conditions
   3.3 System earthing
4 Ratings
   4.1 Standard values of rated primary currents
   4.2 Standard values of rated secondary currents
   4.3 Rated continuous thermal current
   4.4 Standard values of rated output
   4.5 Short-time current ratings
   4.6 Limits of temperature rise
5 Design requirements
   5.1 Insulation requirements
   5.2 Mechanical requirements
6 Classification of tests
   6.1 Type tests
   6.2 Routine tests
   6.3 Special tests
7 Type tests
   7.1 Short-time current tests
   7.2 Temperature-rise test
   7.3 Impulse tests on primary winding
   7.4 Wet test for outdoor type transformers
   7.5 Radio interference voltage measurement
8 Routine tests
   8.1 Verification of terminal markings
   8.2 Power-frequency withstand tests on primary
        windings and partial discharge measurement
   8.3 Power-frequency withstand tests between sections
        of primary and secondary windings and on secondary
        windings
   8.4 Inter-turn overvoltage test
9 Special tests
   9.1 Chopped impulse test on primary winding
   9.2 Measurement of capacitance and dielectric
        dissipation factor
   9.3 Mechanical tests
   9.4 Transmitted overvoltages measurement
10 Markings
   10.1 Terminal markings - General rules
   10.2 Rating plate markings
11 Additional requirements for measuring current
   transformers
   11.1 Accuracy class designation for measuring current
        transformers
   11.2 Limits of current error and phase displacement
        for measuring current transformers
   11.3 Extended current ratings
   11.4 Type tests for accuracy of measuring current
        transformers
   11.5 Routine tests for accuracy of measuring current
        transformers
   11.6 Instrument security current
   11.7 Marking of the rating plate of a measuring
        current transformer
12 Additional requirements for protective current
   transformers
   12.1 Standard accuracy limit factors
   12.2 Accuracy classes for protective current transformer
   12.3 Limits of errors for protective current transformers
   12.4 Type and routine tests for current error and
        phase displacement of protective current transformers
   12.5 Type tests for composite error
   12.6 Routine tests for composite error
   12.7 Marking of the rating plate of a protective
        current transformer
13 Additional requirements for class PR protective current
   transformers
   13.1 Standard accuracy limit factors
   13.2 Accuracy classes for class PR protective current
        transformers
   13.3 Limits of error for class PR protective current
        transformers
   13.4 Type and routine tests for current error and
        phase displacement of class PR protective current
        transformers
   13.5 Marking of rating plate of class PR current
        transformers
14 Additional requirements for class PX protective current
   transformers
   14.1 Specification of performance for class PX
        protective current transformers
   14.2 Insulation requirements for class PX protective
        current transformers
   14.3 Type tests for class PX protective current
        transformers
   14.4 Routine tests for class PX protective current
        transformers
   14.5 Marking of rating plate of class PX current
        transformers
Annex A (normative) - Protective current transformers
Annex B (informative) - Multiple chopped impulse test
Figures
Tables

Applies to newly manufactured current transformers for use withelectrical measuring instruments and electrical protective devicesat frequencies from 15 Hz to 100 Hz. Applies basically totransformers with separate windings, but also to autotransformers.This consolidated version consists of the first edition (1996),its amendment 1 (2000) and its amendment 2 (2002). Therefore, no need to order amendments in addition to this publication.

Committee
TC 38
DevelopmentNote
Supersedes IEC 60185 (03/2001) Also numbered as BS EN 60044-1 (06/2001)
DocumentType
Standard
Pages
111
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

⚠

A newer version of this standard is available.

View Current Edition View Current Edition