• IEC 60076-7:2018

    Current The latest, up-to-date edition.

    Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  12-01-2018

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviations
    5 Effect of loading beyond nameplate rating
    6 Relative ageing rate and transformer insulation life
    7 Limitations
    8 Determination of temperatures
    9 Influence of tap-changers
    Annex A (informative) - Insulation life expectancy and relative
            ageing rate considering oxygen and water effect
    Annex B (informative) - Core temperature
    Annex C (informative) - Specification of loading beyond rated
            power
    Annex D (informative) - Description of Q, S and H factors
    Annex E (informative) - Calculation of winding and oil time
            constant
    Annex F (informative) - Thermal model parameters
    Annex G (informative) - Oil and winding exponents
    Annex H (informative) - Practical example of the exponential
            equations method
    Annex I (informative) - Application of the difference equation
            solution method
    Annex J (informative) - Flowchart, based on the example in
            Annex H
    Annex K (informative) - Example of calculating and presenting
            overload data
    Annex L (informative) - Geomagnetic induced currents
    Annex M (informative) - Alternative oils
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 60076-7:2018 is now available as IEC 60076-7:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

    IEC 60076-7:2018 is applicable to mineral-oil-immersed transformers. It describes the effect of operation under various ambient temperatures and load conditions on transformer life. This document provides guidance for the specification and loading of power transformers from the point of view of operating temperatures and thermal ageing. It provides recommendations for loading above the nameplate rating and guidance for the planner to choose appropriate rated quantities and loading conditions for new installations. This edition includes the following significant technical changes with respect to the previous edition:
    a) title has been updated from "oil-immersed power transformers" to "mineral-oil-immersed transformers";
    b) insulation life is updated by considering latest research findings;
    c) temperature limits have been reviewed and maximum core temperature is recommended;
    d) number of fibre optic sensors is recommended for temperature rise test;
    e) Q, S and H factors are considered;
    f) thermal models are revised and rewritten in generally applicable mathematical form;
    g) geomagnetic induced currents are briefly discussed and corresponding temperature limits are suggested;
    h) extensive literature review has been performed and a number of references added to bibliography.

    General Product Information - (Show below) - (Hide below)

    Committee TC 14
    Development Note Supersedes IEC 60354. (12/2005) Stability Date: 2023. (01/2018)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
    IEC 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    IEC 62770:2013 Fluids for electrotechnical applications - Unused natural esters for transformers and similar electrical equipment
    IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
    IEC 60354:1991 Loading guide for oil-immersed power transformers
    IEC 60076-1:2011 Power transformers - Part 1: General
    IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
    IEEE C57.100-2011 IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers
    IEEE C57.119-2001 IEEE Recommended Practice for Performing Temperature Rise Tests on Oil-Immersed Power Transformers at Loads Beyond Nameplate Ratings
    IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
    ASTM D 982 : 2016 : REDLINE Standard Test Method for Organic Nitrogen in Paper and Paperboard
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective