IEC 60079-6:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
Hardcopy , PDF
English - French
20-02-2015
26-02-2020
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Constructional requirements
5 Protective Liquid
6 Verifications and tests
7 Marking
8 Instructions
Annex A (normative) - Selection and erection requirements
Annex B (normative) - Maintenance requirements
Annex C (normative) - Repair and Overhaul requirements
Bibliography
IEC 60079-6:2015 specifies the requirements for the design, construction, testing and marking of Ex Equipment and Ex Components with type of protection liquid immersion "o" intended for use in explosive gas atmospheres. Ex Equipment and Ex Components of type of protection liquid immersion "o" are either:
- Level of Protection "ob" (EPL "Mb" or "Gb") or
- Level of Protection "oc" (EPL "Gc"). For Level of Protection "ob", this standard applies where the rated voltage does not exceed 11 kV r.m.s. a.c. or d.c. For Level of Protection "oc", this standard applies where the rated voltage does not exceed 15 kV r.m.s. a.c. or d.c. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fourth edition cancels and replaces the third edition, published in 2007. This edition constitutes a technical revision. The significant changes with respect to the previous edition are:
- Edition 4 represents a major technical revision of the requirements for oil immersion "o" and should be considered as introducing all new requirements. The normal "Table of Significant Changes" has not been included for this reason. In particular:
- The requirements for oil immersion "o" have been redefined into liquid immersion, levels of protection "ob" and "oc" as recommended by the responses to 31/715/DC;
- The ability to protect sparking contacts has been added to both "ob" and "oc". Additional requirements have been introduced for the protective liquid. Keywords: Ex Equipment and Ex Components with type of protection liquid immersion "o"
| Committee |
TC 31
|
| DevelopmentNote |
To be read in conjunction with IEC 60079-0. (03/2007) Stability date: 2019. (02/2015) NEW CHILD AMD 1 2020 IS ADDED
|
| DocumentType |
Standard
|
| Pages |
54
|
| ProductNote |
NEW CHILD AMD 1 2020 IS ADDED
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| IS/IEC 60079 : Part 6 : 2016 | Identical |
| NF EN 60079-6 : 2016 | Identical |
| CEI EN 60079-6 : 2016 | Identical |
| NBN EN 60079-6 : 2016 | Identical |
| NEN EN IEC 60079-6 : 2015 | Identical |
| AS/NZS 60079.6:2015 | Identical |
| EN 60079-6:2015 | Identical |
| CEI EN 60079-6:2017 | Identical |
| I.S. EN 60079-6:2015 | Identical |
| DS EN 60079-6 : 2015 | Identical |
| SAC GB 3836-6 : 2004 | Identical |
| NEN EN 50015 : 1998 | Identical |
| UNE 20326:1970 | Identical |
| BS EN 60079-6:2015 | Identical |
| UNE-EN 60079-6:2016 | Identical |
| VDE 0170-2:2016-06 | Identical |
| GOST R IEC 60079-6 : 2012 | Identical |
| NBR IEC 60079-6 : 2017 | Identical |