IEC 60126:1973
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEC reference coupler for the measurement of hearing aids using earphones coupled to the ear by means of ear inserts
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
16-08-2006
English - French, Russian
01-01-1973
Foreword
Preface
Clause
1 Scope and object
2 Definition
3 Construction
3.1 General
3.2 The cavity
3.3 Calibrated pressure microphone
3.4 Connection of the hearing aid to the coupler
Describes a coupler for loading the earphone with a specified acoustic impedance when determining the physical performance characteristics, in the frequency range 200 Hz to 5 000 Hz, of air-conduction hearing aids using earphones coupled to the ear by means of ear inserts, e.g. ear moulds or similar devices. The use of this coupler does not allow the actual performance of a hearing aid on a person to be obtained. Its use is recommended as a simple and ready means for the exchange of specifications and of physical data on hearing aids.
Committee |
TC 29
|
DevelopmentNote |
Also numbered as BS 6111(1981) (09/2005)
|
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NEN 10126 : 1988 | Identical |
HD 305 : 200S1 | Identical |
BIS IS 10781 : 1984(R2001) | Identical |
UNE 20604:1980 | Identical |
GOST R IEC 60126 : 2001 | Identical |
BS 6083-10:1988 | Hearing aids Guide to hearing aid standards |
BS ISO 389-4 : 1994 AMD 10484 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - REFERENCE LEVELS FOR NARROWBAND MASKING NOISE |
BS EN ISO 389-2:1997 | Acoustics. Reference zero for the calibration of audiometric equipment Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
EN 61027 : 1993 | SPECIFICATION FOR INSTRUMENTS FOR THE MEASUREMENT OF AURAL ACOUSTIC IMPEDANCE/ADMITTANCE |
EN 60645-5:2005 | Electroacoustics - Audiometric equipment - Part 5: Instruments for the measurement of aural acoustic impedance/admittance |
11/30253839 DC : 0 | BS EN 60118-0 ED.3 - ELECTROACOUSTICS- HEARING AIDS - PART 0: MEASUREMENT OF THE PERFORMANCE CHARACTERISTICS OF HEARING AIDS (AMALGAMATED REVISION OF IEC 60118-0, IEC 60118-1, IEC 60118-2, IEC 60118-6) |
CEI EN 60645-1 : 2016 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY |
BS 6083-7(1985) : 1985 AMD 7837 | HEARING AIDS - METHODS FOR MEASUREMENT OF THE PERFORMANCE CHARACTERISTICS OF HEARING AIDS FOR QUALITY INSPECTION ON DELIVERY |
BS 6083-0(1984) : 1984 AMD 7836 | HEARING AIDS - METHODS FOR MEASUREMENT OF ELECTROACOUSTICAL CHARACTERISTICS |
I.S. EN ISO 389-4:1999 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - PART 4: REFERENCE LEVELS FOR NARROW-BAND MASKING NOISE |
05/30133728 DC : DRAFT MAY 2005 | EN 71-1 - SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
BS ISO 389-2 : 1994 AMD 9427 | ACOUSTICS - REFERENCE ZERO FOR THE CALIBRATION OF AUDIOMETRIC EQUIPMENT - REFERENCE EQUIVALENT THRESHOLD SOUND PRESSURE LEVELS FOR PURE TONES AND INSERT EARPHONES |
ISO 389-4:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise |
IEC 60645-5:2004 | Electroacoustics - Audiometric equipment - Part 5: Instruments for the measurement of aural acoustic impedance/admittance |
PD 6545:2005 | Intended use of human head and ear simulators-guide |
00/203722 DC : DRAFT AUG 2000 | IEC 60118-13. ED.2 - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATIBILITY (EMC) - PRODUCT STANDARD |
BS EN 60645-5:2005 | Electroacoustics. Audiometric equipment Instruments for the measurement of aural acoustic impedance/admittance |
ISO 389-2:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
BS EN ISO 389-4:1999 | Acoustics. Reference zero for the calibration of audiometric equipment Reference levels for narrow-band masking noise |
IEC 61027:1991 | Instruments for the measurement of aural acoustic impedance/admittance |
EN ISO 389-2:1996 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones (ISO 389-2:1994) |
EN ISO 389-4:1998 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 4: Reference levels for narrow-band masking noise (ISO 389-4:1994) |
IEEE DRAFT C63.19 : 2005 | METHODS OF MEASUREMENT OF COMPATIBILITY BETWEEN WIRELESS COMMUNICATIONS DEVICES AND HEARING AIDS |
04/30117001 DC : DRAFT JUL 2004 | IEC 60645-3. ED.2.0 - AUDIOMETERS - PART 3: AUDITORY TEST SIGNALS OF SHORT DURATION FOR AUDIOMETRIC AND NEURO-OTOLOGICAL PURPOSES |
BS EN 61027:1993 | Specification for instruments for the measurement of aural acoustic impedance/admittance |
I.S. EN 60645-5:2005 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 5: INSTRUMENTS FOR THE MEASUREMENT OF AURAL ACOUSTIC IMPEDANCE/ADMITTANCE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.