• IEC 60172:2015

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  31-12-2021

    Language(s):  English - French, Spanish, Castilian

    Published date:  12-05-2015

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Summary of procedure
    5 Test specimens
    6 Temperature exposure
    7 Test voltage and its application
    8 Calculations
    9 Report
    Annex A (normative) - Method for calculation of the
            regression line
    Annex B (normative) - Correlation coefficient
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 60172:2015 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. This fourth edition cancels and replaces the third edition published in 1987, Amendment 1:1997 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    - Revision of Clause 1, Scope, to incorporate appropriate text from former Clause 2, Object;
    - Deletion of Clause 2, Object, by placement of its text into existing clauses;
    - New Clause 2, Normative references;
    - Revision of 5.1.1, 5.3 and 5.4 with corrections to Amendment 2 to the third edition;
    - Revision of Clause 7 as to clarify which specimens comply with Table 3 and Table 4;
    - Revision of figures with high-resolution photos and graphs. Keywords: enamelled wire, tape wrapped round and rectangular wire, AC proof voltage tests

    General Product Information - (Show below) - (Hide below)

    Development Note Stability Date: 2018. (05/2015)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    02/208319 DC : DRAFT SEP 2002 IEC 60455-3-5 ED.3 - RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 5: UNSATURATED POLYESTER BASED IMPREGNATING RESINS
    PD IEC/TS 62332-3:2016 Electrical insulation systems (EIS). Thermal evaluation of combined liquid and solid components Hermetic motor-compressors
    13/30284348 DC : 0 BS EN 60317-0-9 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-9: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR ALUMINIUM WIRE
    CEI EN 60034-18-22 : 2001 ROTATING ELECTRICAL MACHINES - PART 18-22: FUNCTIONAL EVALUATION OF INSULATION SYSTEMS - TEST PROCEDURES FOR WIRE-WOUND WINDINGS - CLASSIFICATION OF CHANGES AND INSULATION COMPONENT SUBSTITUTIONS
    ASTM D 2293 : 1996 : R2008 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    BS EN 60317-52:2014 Specifications for particular types of winding wires Aromatic polyamide (aramid) tape wrapped round copper wire, temperature index 220
    BS IEC 61858-2 : 2014 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS
    BS EN 60455-3-5:2006 Resin based reactive compounds used for electrical insulation Specifications for individual materials - Unsaturated polyester based impregnating resins
    09/30200601 DC : 0 BS EN 60317-44 A1 ED.1 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 44: AROMATIC POLYIMIDE TAPE WRAPPED RECTANGULAR COPPER WIRE, CLASS 240
    BS EN 60464-3-2:2002 Varnishes used for electrical insulation Requirements for hot curing impregnating varnishes
    BS EN 61858-2:2014 Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS
    BS EN 60216-2:2005 Electrical insulating materials. Thermal endurance properties Determination of thermal endurance properties of electrical insulating materials. Choice of test criteria
    I.S. EN 60317-43:1998 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 43: AROMATIC POLYIMIDE TAPE WRAPPED ROUND COPPER WIRE, CLASS 240
    ASTM D 2293 : 1996 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2294 : 1996 : R2008 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2310 : 2006 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2303 : 1997 : R2004 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    BIS IS 13730-44 : 2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 44: AROMATIC POLYMIDE TAPE WRAPPED RECTANGULAR COPPER WIRE, CLASS 240
    ASTM D 2310 : 2006 : R2012 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2318 : 1998 : R2008 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2308 : 2007 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    I.S. EN 60044-8:2002 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS
    ASTM D 2293 : 1996 : R2002 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    I.S. EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
    BS EN 60317-44 : 1997 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 44: AROMATIC POLYIMIDE TAPE WRAPPED RECTANGULAR COPPER WIRE, CLASS 240
    CEI EN 60317-0-7 : 2012 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-7: GENERAL REQUIREMENTS - FULLY INSULATED (FIW) ZERODEFECT ENAMELLED ROUND COPPER WIRE
    BIS IS 13730-43 : 2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 43: AROMATIC POLYMIDE TAPE WRAPPED ROUND COPPER WIRES, CLASS 240
    NF EN 60216-2 : 2006 ELECTRICAL INSULATING MATERIALS - THERMAL ENDURANCE PROPERTIES - PART 2: DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - CHOICE OF TEST CRITERIA
    ASTM D 2852 : 1995 : R2008 Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings
    UNE-EN 60317-53:2014 Specifications for particular types of winding wires - Part 53: Aromatic polyamide (aramid) tape wrapped rectangular copper wire, temperature index 220
    UNE-EN 60851-6:2012 Winding wires - Test methods - Part 6: Thermal properties
    EN 60034-18-41:2014 Rotating electrical machines - Part 18-41: Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters - Qualification and quality control tests
    EN 60317-52:2014 Specifications for particular types of winding wires - Part 52: Aromatic polyamide (aramid) tape wrapped round copper wire, temperature index 220
    EN 60216-2:2005 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
    EN 60464-3-2:2001/A1:2006 VARNISHES USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 2: HOT CURING IMPREGNATING VARNISHES
    EN 60455-3-5:2006 Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 5: Unsaturated polyester based impregnating resins
    EN 61858-2:2014 Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS
    EN 60317-0-1:2014 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire
    EN 60317-0-9:2015 Specifications for particular types of winding wires - Part 0-9: General requirements - Enamelled rectangular aluminium wire
    EN 60317-53:2014 Specifications for particular types of winding wires - Part 53: Aromatic polyamide (aramid) tape wrapped rectangular copper wire, temperature index 220
    03/307567 DC : DRAFT JUNE 2003 IEC 61858 ED.2.0 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
    BIS IS 8504-2 : 2013 ELECTRICAL INSULATING MATERIALS - THERMAL ENDURANCE PROPERTIES - PART 2: DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - CHOICE OF TEST CRITERIA
    BS EN 60851-6:1998 Methods of test for winding wires Thermal properties
    I.S. EN 60034-18-41:2014 ROTATING ELECTRICAL MACHINES - PART 18-41: PARTIAL DISCHARGE FREE ELECTRICAL INSULATION SYSTEMS (TYPE 1) USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS - QUALIFICATION AND QUALITY CONTROL TESTS
    BS EN 60034-18-22:2001 Rotating electrical machines. Functional evaluation of insulation systems Test procedures for wire-wound windings. Classification of changes and insulation component substitutions
    ASTM D 2854 : 1996 : R2004 Standard Test Method for Apparent Density of Activated Carbon
    12/30273912 DC : 0 BS EN 61858-2 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-2: FORM-WOUND EIS
    12/30276801 DC : 0 BS EN 60317-52 ED 2.0 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 52: AROMATIC POLYAMIDE (ARAMID) TAPE WRAPPED ROUND COPPER WIRE, TEMPERATURE INDEX 220
    CEI EN 60317-0-3 : 2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-3: GENERAL REQUIREMENTS - ENAMELLED ROUND ALUMINIUM WIRE
    I.S. EN 60464-3-2:2001 VARNISHES USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 2: HOT CURING IMPREGNATING VARNISHES
    ASTM D 2318 : 1998 : R2003 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2295 : 1996 : R2008 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    09/30200593 DC : 0 BS EN 60317-43 A1 ED.1 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 43: AROMATIC POLYIMIDE TAPE WRAPPED ROUND COPPER WIRE, CLASS 240
    ASTM D 2295 : 1996 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    NF EN 60455 3-5 : 2006 RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 5: UNSATURATED POLYESTER BASED IMPREGNATING RESINS
    ASTM D 2303 : 1997 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2307 : 2007 : R2013 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2288 : 1997 : R2001 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2300 : 2008 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2293 : 1996 : R2016 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2300 : 2008 : R2017 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2296 : 2001 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2295 : 1996 : R2016 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    BS EN 60317-0-3 : 2008 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-3: GENERAL REQUIREMENTS - ENAMELLED ROUND ALUMINIUM WIRE
    IEEE 101 : 1987 GUIDE FOR THE STATISTICAL ANALYSIS OF THERMAL LIFE TEST DATA
    CEI EN 60317-0-2 : 2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-2: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR COPPER WIRE
    ASTM D 2852 : 1995 : R2002 Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings
    ASTM D 2307 : 2007 : REV A Standard Test Method for Thermal Endurance of Film-Insulated Round Magnet Wire
    I.S. EN 60317-0-9:2015 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-9: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR ALUMINIUM WIRE
    IEC TS 62332-3:2016 Electrical insulation systems (EIS) - Thermal evaluation of combined liquid and solid components - Part 3: Hermetic motor-compressors
    IEC 60317-0-1:2013 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire
    VDE 0304-22 : 2006 Electrical insulating materials - Thermal endurance properties Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria (IEC 60216-2:2005); German version EN 60216-2:2005
    BS 5691-2:1995 Guide for the determination of thermal endurance properties of electrical insulating materials Choice of test criteria
    ASTM D 3251 : 2004 : R2013 Standard Test Method for Thermal Endurance Characteristics of Electrical Insulating Varnishes Applied Over Film-Insulated Magnet Wire
    NF EN 61858 : 2009 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
    BS EN 60317-53:2014 Specifications for particular types of winding wires Aromatic polyamide (aramid) tape wrapped rectangular copper wire, temperature index 220
    ASTM D 2851 : 1998 : R2009 Standard Specification for Liquid Optical Adhesive
    12/30273916 DC : 0 BS EN 61858-1 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-1: WIRE-WOUND WINDING EIS
    BS EN 60034-18-41:2014 Rotating electrical machines Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters. Qualification and quality control tests
    08/30177151 DC : DRAFT JAN 2008 BS EN 61858 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
    NF EN 60034-18-22 : 2001 ROTATING ELECTRICAL MACHINES - PART 18-22: FUNCTIONAL EVALUATION OF INSULATION SYSTEMS - TEST PROCEDURES FOR WIRE-WOUND WINDINGS - CLASSIFICATION OF CHANGES AND INSULATION COMPONENT SUBSTITUTIONS
    NF EN 60464 3-2 : 2002 AMD 1 2006 VARNISHES USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 2: HOT CURING IMPREGNATING VARNISHES
    BS EN 61858-1:2014 Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Wire-wound winding EIS
    BS EN 61858:2008 Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS
    IEC 60317-0-7:2017 Specifications for particular types of winding wires - Part 0-7: General requirements - Fully insulated (FIW) zero-defect enamelled round copper wire
    05/30133636 DC : DRAFT MAY 2005 IEC 60317-55 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 55: SOLDERABLE POLYURETHANE ENAMELED ROUND COPPER WIRE OVERCOATED WITH POLYAMIDE, CLASS 180
    ASTM D 2288 : 1997 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    03/321547 DC : DRAFT DEC 2003 IEC 60216-2 ED.4 - ELECTRICAL INSULATING MATERIALS - THERMAL ENDURANCE PROPERTIES - PART 2: GUIDE FOR THE DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - CHOICE OF TEST CRITERIA
    ASTM D 2307 : 2007A TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2301 : 2010 : R2017 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2295 : 1996 : R2002 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2288 : 1997 : R2001 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2318 : 1998 : R2013 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    I.S. EN 60317-44:1998 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - AROMATIC POLYIMIDE TAPE WRAPPED RECTANGULAR COPPER WIRE, CLASS 240
    I.S. EN 61858-2:2014 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS
    IEC TS 60034-18-41:2006 Rotating electrical machines - Part 18-41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters
    ASTM D 2307 : 2007 Standard Test Method for Thermal Endurance of Film-Insulated Round Magnet Wire
    IEC 60034-18-22:2000 Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions
    IEC 60317-0-9:2015 Specifications for particular types of winding wires - Part 0-9: General requirements - Enamelled rectangular aluminium wire
    IEC 60216-2:2005 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
    EN 60317-0-2:2014 Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire
    ASTM D 2296 : 2001 : R2006 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    08/30189113 DC : 0 BS EN 60317-57 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 57: POLYAMIDE-IMIDE ENAMELED ROUND COPPER WIRE, CLASS 220
    CEI EN 60034-18-41 : 2014 ROTATING ELECTRICAL MACHINES - PART 18-41: PARTIAL DISCHARGE FREE ELECTRICAL INSULATION SYSTEMS (TYPE I) USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS - QUALIFICATION AND QUALITY CONTROL TESTS
    EN 60034-18-22:2001 Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions
    ASTM D 3251 : 2004 Standard Test Method for Thermal Endurance Characteristics of Electrical Insulating Varnishes Applied Over Film-Insulated Magnet Wire
    12/30276805 DC : 0 BS EN 60317-53 ED 2.0 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 53: AROMATIC POLYAMIDE (ARAMID) TAPE WRAPPED RECTANGULAR COPPER WIRE, TEMPERATURE INDEX 220
    10/30238620 DC : 0 BS EN 60034-18-41 TS ED - ROTATING ELECTRICAL MACHINES - PART 18-41: QUALIFICATION AND QUALITY CONTROL TESTS FOR PARTIAL DISCHARGE FREE (TYPE 1) ELECTRICAL INSULATION SYSTEMS USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS
    I.S. EN 60317-53:2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 53: AROMATIC POLYAMIDE (ARAMID) TAPE WRAPPED RECTANGULAR COPPER WIRE, TEMPERATURE INDEX 220
    08/30176410 DC : DRAFT JULY 2008 BS EN 60317-0-7 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-7: GENERAL REQUIREMENTS - FULLY INSULATED (FIW) ZERO-DEFECT ENAMELLED WINDING WIRES
    11/30257662 DC : 0 BS EN 60317-0-2 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-2: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR COPPER WIRE
    BS EN 60317-43 : 1997 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 43: AROMATIC POLYIMIDE TAPE WRAPPED ROUND COPPER WIRE, CLASS 240
    I.S. EN 60455-3-5:2006 RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 5: UNSATURATED POLYESTER BASED IMPREGNATING RESINS
    ASTM D 2307 : 2007 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    EN 60317-0-7:2017 Specifications for particular types of winding wires - Part 0-7: General requirements - Fully insulated (FIW) zero-defect enamelled round copper wire
    I.S. EN 60851-6:2012 WINDING WIRES - TEST METHODS - PART 6: THERMAL PROPERTIES (IEC 60851-6:2012 (EQV))
    I.S. EN 60317-0-3:2008 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-3: GENERAL REQUIREMENTS - ENAMELLED ROUND ALUMINIUM WIRE
    I.S. EN 61858-1:2014 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 1: WIRE-WOUND WINDING EIS
    CEI EN 60216-2 : 2006 ELECTRICAL INSULATING MATERIALS - THERMAL ENDURANCE PROPERTIES - PART 2: DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - CHOICE OF TEST CRITERIA
    I.S. EN 60317-0-7:2017 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-7: GENERAL REQUIREMENTS - FULLY INSULATED (FIW) ZERO-DEFECT ENAMELLED ROUND COPPER WIRE
    GOST 849:2018 Primary nickel. SpecificationsE
    I.S. EN 60317-0-1:2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-1: GENERAL REQUIREMENTS - ENAMELLED ROUND COPPER WIRE
    UNE-EN 60317-52:2014 Specifications for particular types of winding wires - Part 52: Aromatic polyamide (aramid) tape wrapped round copper wire, temperature index 220
    IEC 60317-0-2:2013 Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire
    IEC 60851-6:2012 Winding wires - Test methods - Part 6: Thermal properties
    IEC 60317-52:2014 Specifications for particular types of winding wires - Part 52: Aromatic polyamide (aramid) tape wrapped round copper wire, temperature index 220
    IEC 60317-0-3:2008+AMD1:2013 CSV Specifications for particular types of winding wires - Part 0-3:General requirements - Enamelled round aluminium wire
    IEC 61858-1:2014 Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 1: Wire-wound winding EIS
    UNE-EN 60317-44:1997 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES. PART 44: AROMATIC POLYIMIDE TAPE WRAPPED RECTANGULAR COPPER WIRE, CLASS 240.
    IEC 61858-2:2014 Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS
    IEC 60317-43:1997+AMD1:2010 CSV Specifications for particular types of winding wires - Part 43: Aromatic polyimide type wrapped round copper wire, class 240
    IEC 60317-44:1997+AMD1:2010 CSV Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240
    IEC 60034-18-41:2014 Rotating electrical machines - Part 18-41: Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters - Qualification and quality control tests
    IEC 60455-3-5:2006 Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 5: Unsaturated polyester based impregnating resins
    BIS IS 13730-0-3 : 2012(R2017) SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0: GENERAL REQUIREMENTS - SECTION 3: ENAMELLED ROUND ALUMINIUM WIRE
    I.S. EN 60317-52:2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 52: AROMATIC POLYAMIDE (ARAMID) TAPE WRAPPED ROUND COPPER WIRE, TEMPERATURE INDEX 220
    ASTM D 2308 : 2007 : R2013 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2319/D2319M : 1998 : R2008e1 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    BS EN 60317-0-1:2014 Specifications for particular types of winding wires General requirements. Enamelled round copper wire
    11/30247071 DC : 0 BS EN 60851-6 - WINDING WIRES - TEST METHODS - PART 6: THERMAL PROPERTIES
    CEI EN 60317-0-1 : 2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-1: GENERAL REQUIREMENTS - ENAMELLED ROUND COPPER WIRE
    BS EN 60317-0-7:2017 Specifications for particular types of winding wires General requirements. Fully insulated (FIW) zero-defect enamelled round copper wire
    BS EN 60317-0-9:2015 Specifications for particular types of winding wires General requirements. Enamelled rectangular aluminium wire
    BS EN 60317-0-2:2014 Specifications for particular types of winding wires General requirements. Enamelled rectangular copper wire
    ASTM D 3251 : 2004 : R2009 Standard Test Method for Thermal Endurance Characteristics of Electrical Insulating Varnishes Applied Over Film-Insulated Magnet Wire
    ASTM D 2307 : 2007A : R2013 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2319/D2319M : 1998 : R2013 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2294 : 1996 : R2016 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2301 : 2010 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    ASTM D 2294 : 1996 : R2002 TEST METHOD FOR WEIGHT LOSS OF PLASTICIZERS ON HEATING
    UNE-EN 60317-0-9:2016 Specifications for particular types of winding wires - Part 0-9: General requirements - Enamelled rectangular aluminium wire
    CEI EN 60455-3-5 : 2006 RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 5: UNSATURATED POLYESTER BASED IMPREGNATING RESINS
    I.S. EN 60216-2:2005 ELECTRICAL INSULATING MATERIALS - THERMAL ENDURANCE PROPERTIES - PART 2: DETERMINATION OF THERMAL ENDURANCE PROPERTIES OF ELECTRICAL INSULATING MATERIALS - CHOICE OF TEST CRITERIA
    NF EN 60317 0-3 : 2008 AMD 1 2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-3: GENERAL REQUIREMENTS - ENAMELLED ROUND ALUMINIUM WIRE
    UNE-EN 60317-0-7:2012 Specifications for particular types of winding wires - Part 0-7: General requirements - Fully insulated (FIW) zero-defect enamelled round copper wire with nominal conductor diameter of 0,040 mm to 1,600 mm
    I.S. EN 60317-0-2:2014 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-2: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR COPPER WIRE
    IEC 61858:2008 Electrical insulation systems - Thermal evaluation of modifications to an established wire-wound EIS
    IEC 60464-3-2:2001+AMD1:2006 CSV Varnishes used for electrical insulation - Part 3: Specificationsfor individual materials - Sheet 2: Hot curing impregnating varnishes
    IEC 60317-53:2014 Specifications for particular types of winding wires - Part 53: Aromatic polyamide (aramid) tape wrapped rectangular copper wire, temperature index 220
    EN 61858-1:2014 Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 1: Wire-wound winding EIS
    EN 60317-44:1997/A1:2010 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 44: AROMATIC POLYIMIDE TAPE WRAPPED RECTANGULAR COPPER WIRE, CLASS 240
    EN 60317-43:1997/A1:2010 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 43: AROMATIC POLYIMIDE TAPE WRAPPED ROUND COPPER WIRE, CLASS 240
    EN 60044-8:2002 Instrument transformers - Part 8: Electronic current transformers
    EN 61858:2008 ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS
    EN 60851-6:2012 Winding wires - Test methods - Part 6: Thermal properties
    EN 60317-0-3:2008/A1:2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-3: GENERAL REQUIREMENTS - ENAMELLED ROUND ALUMINIUM WIRE (IEC 60317-0-3:2008/A1:2013)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60455-3-5:2006 Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 5: Unsaturated polyester based impregnating resins
    IEC 60464-3-2:2001+AMD1:2006 CSV Varnishes used for electrical insulation - Part 3: Specificationsfor individual materials - Sheet 2: Hot curing impregnating varnishes
    IEC 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
    IEC 60216-3:2006 Electrical insulating materials - Thermal endurance properties - Part 3: Instructions for calculating thermal endurance characteristics
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective