• IEC 60265-2:1988

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  20-04-2009

    Language(s): 

    Published date:  15-03-1988

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    Specification
    1. Scope
    2. Normal and special service conditions
    3. Definitions
    4. Rating
    5. Design and construction
    6. Type tests
    7. Routine tests
    8. Guide to the selection of high-voltage switches for
         service
    9. Information to be given with enquiries, tenders and
         orders
    Annex
    ZA. Special national conditions (normative)
    Tables
    I. Rated line and cable charging breaking currents
         for a general purpose switch
    II. Nameplate information
    III. Supply circuit TRV parameters for mainly active
         load current breaking tests
    IVA. TRV parameters for transmission line closed loop
         current breaking tests
    IVB. TRV parameters for parallel transformer current
         breaking tests
    V. TRV parameters for shunt reactor current breaking
         tests
    VI. Test-duties for three phase tests on three-pole
         switches
    VIIA.Test duties for single phase tests on three-pole
         switches with 0.5 cycle or less non-simultaneity
    VIIB.Test-duties for single phase tests on three-pole
         switches with more than 0.5 cycle non-simultaneity
         and switches operated pole after pole
    VIII.Recovery voltage requirements for single-phase
         capacitative current breaking tests
    IX. Suggested maximum permissible switching overvoltages
         when switching capacitive and inductive currents

    Abstract - (Show below) - (Hide below)

    Applicable to three-phase alternating-current switches, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages 52 kV and above, and for rated frequencies up to and including 60 Hz.The contents of the corrigendum of February 1990 have been included in this copy.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN 62271-205:2011 High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV
    I.S. EN 62271-102:2005 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV))
    I.S. EN 61642:1999 INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS
    NF EN 62271-205 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
    EN 61642:1997 Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors
    EN 62271-205:2008/corrigendum:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
    EN 62271-102:2002/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013)
    BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
    BS EN 61642:1998 Industrial a.c. networks affected by harmonics. Application of filters and shunt capacitors
    CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    VDE 0560-430 : 1998 INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS
    DIN EN 61642 : 1998 INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS
    BS EN 62271-102 : 2002 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES
    BS 5463-2(1991) : 1991 AMD 8051 SPECIFICATION FOR HIGH-VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 kV AND ABOVE
    DD IEC/PAS 62001:2004 Guide to the specification and design evaluation of a.c. filters for HVDC systems
    I.S. EN 62271-205:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
    IEC PAS 62001:2004 Guide to the specification and design evaluation of a.c. filters for HVDC systems
    UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    CEI EN 62271-205 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
    IEC 62271-205:2008 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
    EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
    BS EN 62271-205:2008 High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV
    IEEE 1247 : 2005 INTERRUPTER SWITCHES FOR ALTERNATING CURRENT, RATED ABOVE 1000 V
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective