IEC 60317-18:2004+AMD1:2009 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Specifications for particular types of winding wires - Part 18: Polyvinyl acetal enamelled rectangular copper wire, class 120
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
03-05-2022
English - French
25-02-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions and general notes on methods of test and
appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Soderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging
IEC 60317-18:2004+A1:2009 specifies the requirements of enamelled rectangular copper winding wire of class 120 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. Class 120 is a thermal class that requires a minimum temperature index of 120 and a heat shock temperature of at least 155 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor dimensions covered by this standard is as follows:
- width: maximum 16,0 mm;
- thickness: maximum 5,60 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2. The main changes with respect to the previous edition are listed below:
- new requirements for appearance, Subclause 3.2, added;
- new pin hole test, Clause 23, added.
This consolidated version consists of the third edition (2004) and its amendment 1 (2009). Therefore, no need to order amendment in addition to this publication.
This publication is to be read in conjunction with IEC 60317-0-2:2005.
Committee |
TC 55
|
DevelopmentNote |
To be read in conjunction with IEC 60317-0-2. (08/2004) Stability Date: 2019. (09/2017)
|
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 60317-18 : 2005 AMD 1 2010 | Identical |
NEN EN IEC 60317-18 : 2004 AMD 1 2010 | Identical |
I.S. EN 60317-18:2004 | Identical |
PN EN 60317-18 : 2005 AMD 1 2010 | Identical |
BS EN 60317-18 : 2004 | Identical |
UNE-EN 60317-18:2005 | Identical |
EN 60317-18:2004/A1:2010 | Identical |
DIN EN 60317-18:2010-10 | Identical |
NEN 10317-18 : 1995 | Similar to |
NFC 31 668 : 1988 | Similar to |
I.S. EN IEC 60317-18:2020 | Identical |
CEI 55-2/18 : 4ED 1991 | Identical |
UNE 21179-18:1993 | Identical |
DIN IEC 60317-18 : 1994 | Similar to |
BS IEC 61858-2 : 2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
EN 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
12/30273912 DC : 0 | BS EN 61858-2 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-2: FORM-WOUND EIS |
I.S. EN 61858-2:2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
BS EN 61858-2:2014 | Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS |
11/30257662 DC : 0 | BS EN 60317-0-2 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-2: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR COPPER WIRE |
IEC 60034-18-22:2000 | Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions |
IEC 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
IEC 60317-0-2:2013 | Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire |
IEC 60851-4:2016 | Winding wires - Test methods - Part 4: Chemical properties |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.