• There are no items in your cart

IEC 60331-1:2018 RLV

Current

Current

The latest, up-to-date edition.

Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm

Published date

28-03-2018

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Test specimen (electric power and control cables
   with rated voltage up to and including
   600 V/1000 V)
7 Test procedure (electric power and control cables
   with rated voltage up to and including
   600 V/1000 V)
8 Performance requirements (electric power and
   control cables with rated voltage up to and
   including 600/1000 V)
9 Retest procedure
10 Test report (electric power and control cables with
   rated voltage up to and including 600 V/1000 V)
11 Cable marking
Annex A (normative) - Verification procedure for the
        source of heat
Annex B (informative) - Guidance on the choice of
        recommended test apparatus (burner
        And venturi)
Bibliography

IEC 60331-1:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.

IEC 60331-1:2018 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. This document is applicable to cables of rated voltage not exceeding 600 V/1 000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables. It is intended for use when testing cables of greater than 20 mm overall diameter. Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-2. This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1 000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1. Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used. This second edition cancels and replaces the first edition published in 2009. It constitutes a technical revision. The significant technical changes with respect to the previous edition are as follows:
– extension of the scope to include metallic data and telecom cables and optical fibre cables, although details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1;
– improved description of the test environment;
– modified steel test ladder with two extra vertical elements to accommodate the modified testing of single core cables without concentric metal layer and the testing of cables with a bending radius in normal use larger than approximately 400 mm;
– mandatory use of mass flow meters/controllers as the means of controlling accurately the input flow rates of fuel and air to the burner;
– improved description of the information to be included in the test report.
This document has the status of a group safety publication in accordance with IEC Guide 104.

Committee
TC 20
DevelopmentNote
Stability Date: 2023. (04/2018)
DocumentType
Redline
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

IEC 60331-2:2009 Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
AS/NZS IEC 60092.376:2020 Electrical installations in ships Cables for control and instrumentation circuits 150/250 V (300 V)
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
IEC 61034-1:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.