• Shopping Cart
    There are no items in your cart

IEC 60331-3:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

19-05-2009

Superseded date

12-09-2022

€164.53
Excluding VAT
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Test specimen (electric power and control cables with
   rated voltage up to and including 600 V/1000 V)
7 Test procedure (electric power and control cables
   with rated voltage up to and including 600 V/1000 V)
8 Performance requirements (electric power and control
   cables with rated voltage up to and including 600 V/1000 V)
9 Retest procedure
10 Test report (electric power and control cables with rated
   voltage up to and including 600 V/1000 V)
Annex A (normative) - Verification procedure for the
        source of heat
Annex B (informative) - Guidance on the choice of recommended
        test apparatus (burner And venturi)
Bibliography

IEC 60331-3:2009 specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV, and control cables with a rated voltage which are required to maintain circuit integrity when tested in a metal enclosure and when subject to fire and mechanical shock under specified conditions. This standard describes the means of sample preparation, the continuity checking arrangements, the electrical testing procedure, the method of burning the cables and the method of shock production and gives requirements for evaluating test results. NOTE All cables assessed by this method should first have been assessed against the test of IEC 60331-1 or IEC 60331-2. Such performance may be recognized by the marking according to Clause 11 of IEC 60331-1 or Clause 11 of IEC 60331-2. Annex A provides the method of verification of the burner and control system used for the test. It has the status of a horizontal standard in accordance with IEC Guide 104.

Committee
TC 20
DevelopmentNote
Stability Date: 2023. (04/2018)
DocumentType
Standard
Pages
49
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
AS/NZS IEC 60331.3:2017 Identical
GOST IEC 60331-3 : 2013 Identical

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
€164.53
Excluding VAT