IEC 60335-2-51:2002+AMD1:2008+AMD2:2011 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Household and similar electrical appliances - Safety - Part 2-51: Particular requirements for stationary circulation pumps for heating and service water installations
Hardcopy , PDF
English - French
30-01-2012
12-09-2022
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirement
5 General conditions for the tests
6 Classification
7 Marking and instructions
8 Protection against access to live parts
9 Starting of motor-operated appliances
10 Power input and current
11 Heating
12 Void
13 Leakage current and electric strength at operating
temperature
14 Transient overvoltages
15 Moisture resistance
16 Leakage current and electric strength
17 Overload protection of transformers and associated
circuits
18 Endurance
19 Abnormal operation
20 Stability and mechanical hazards
21 Mechanical strength
22 Construction
23 Internal wiring
24 Components
25 Supply connection and external flexible cords
26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Clearances, creepage distances and solid insulation
30 Resistance to heat and fire
31 Resistance to rusting
32 Radiation, toxicity and similar hazards
Annexes
Bibliography
IEC 60335-2-51:2002+A1:2008+A2:2011 deals with the safety of electric stationary circulation pumps intended for use in heating systems or in service water systems, having a rated power input not exceeding 300 W, their rated voltage being not more than 250 V for single-phase and 480 V for other appliances. Hydraulic and electric parts of the pump may be in the same enclosure, so that the water serves as a coolant, or they maybe seperate. This standard does not apply to:
- pumps for circulating liquids other than water;
- pumps, other than circulation pumps (IEC 60335-2-41);
- circulation pumps intended exclusively for industrial purposes;
- circulation pumps intended for locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapor, or gas).
This publication is to be read in conjunction with IEC 60335-1:2010.
This consolidated version consists of the third edition (2002), its amendment 1 (2008) and its amendment 2 (2011). Therefore, no need to order amendments in addition to this publication.
| DevelopmentNote |
To be used in conjunction with IEC 60335-1. (10/2002) Stability Date: 2017. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
25
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| AS/NZS 60335.2.51:2012 | Identical |
| GOST IEC 60335-2-51 : 2012 | Identical |
| NEN EN IEC 60335-2-51 : 2003 AMD 2 2012 | Identical |
| PN EN 60335-2-51 : 2005 AMD 2 2012 | Identical |
| DIN EN 60335-2-51 : 2012 | Identical |
| VDE 0700-51 : 2012 | Identical |
| BS EN 60335-2-51 : 2003 | Identical |
| NF EN 60335-2-51:2005 AMD 2 2012 | Identical |
| DS EN 60335-2-51 : 2006 AMD 2 2012 | Identical |
| UNE-EN 60335-2-51:2005 | Identical |