IEC 60523:1975
Current
The latest, up-to-date edition.
Direct-current potentiometers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-01-1975
FOREWORD
PREFACE
Clause
1 Scope
2 Terms and definitions
2.1 D.C. potentiometer (hereinafter designated
'potentiometer')
2.2 Measuring dials
2.3 Effective range
2.4 Range-changing device
2.5 Standardization of a potentiometer
2.6 Dial setting
2.7 Auxiliary equipment
2.8 Resolution
2.9 Circuit insulation voltage (nominal circuit
voltage)
2.10 Ripple content
2.11 Leakage current screen (circuit)
2.12 Electrostatic screen
2.13 Measuring terminals
2.14 Measuring circuit
2.15 Measured quantity circuit selector switch
2.16 Residual e.m.f. of a potentiometer
2.17 Incremental linearity
2.18 Influence quantity
2.19 Common mode voltage
2.20 Variation with influence quantity
2.21 Reference conditions
2.22 Reference value
2.23 Reference range
2.24 Nominal range of use
2.25 Limiting values of an influence quantity
2.26 Fiducial value
2.27 Error
2.28 Intrinsic error
2.29 Accuracy
2.30 Accuracy class
2.31 Class index
3 Classification
4 Limits of intrinsic error
4.1 Permissible limits of intrinsic error
4.2 Incremental linearity
4.3 Resolution
4.4 Range-changing device
4.5 Independent circuit for standardization of a
potentiometer
5 Conditions for the determination of intrinsic errors
6 Permissible variations
6.1 Limits of variation
6.2 Conditions for the determination of the variations
6.3 Determination of the effect of a common mode
voltage
6.4 Variation due to the influence of a magnetic field
of external origin
7 Additional electrical and mechanical requirements
7.1 Voltage test and other safety requirements
7.2 Functional insulation test
7.3 Measured quantity circuit selector switches
7.4 Potentiometer adjustments
7.5 Limiting temperature for storage, transport and use
8 Information, markings and symbols
8.1 Information
8.2 Markings, symbols and their locations
8.3 Documentation
8.4 Example of the marking of a potentiometer
Appendices
A - Determination of the effect of common mode
voltage. Direct method
B - Determination of the effect of common mode
voltage. Indirect method (Superposition method)
Applicable to d.c. potentiometers assembled from resistors and switches and operating entirely on direct current, having accuracy classes of 0.0005 ... 0.1, as well as to auxiliary equipment which is a built-in part of the potentiometer. Classification system. Permissible errors for each accuracy class. Conditions for determination of errors. Markings. Information by the manufacturer.
DevelopmentNote |
BS DRAFT 96/203885 DC. Former IEC 523. Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
65
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
UNE-EN 60523:1996 | Identical |
NF EN 60523 : 93 AMD 2 98 | Identical |
GOST IEC 60523 : 2014 | Identical |
NEN EN IEC 60523 : 1993 AMD 2 1998 | Identical |
NEN 10523 : 1993 | Similar to |
I.S. EN 60523:1993 | Identical |
PN EN 60523 : 2004 | Identical |
SN EN 60523 : 1993 AMD 2 1997 | Identical |
BS 5981(1980) : 1980 AMD 7914 | Identical |
BS EN 60523:1993 | Identical |
EN 60523:1993/A2:1997 | Identical |
DIN EN 60523:1994-08 | Similar to |
DIN IEC 60523:1979-02 | Similar to |
IEEE 1709-2010 | IEEE Recommended Practice for 1 kV to 35 kV Medium-Voltage DC Power Systems on Ships |
ISO 23552-1:2007 | Safety and control devices for gas and/or oil burners and gas and/or oil appliances — Particular requirements — Part 1: Fuel/air ratio controls, electronic type |