IEC 60627:2013
Current
The latest, up-to-date edition.
Diagnostic X-ray imaging equipment - Characteristics of general purpose and mammographic anti-scatter grids
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
09-07-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Structure of ANTI-SCATTER GRIDS
5 Measurement and determination of physical
characteristics
6 Requirements for ANTI-SCATTER GRIDS
Annex A (normative) - Calculation of the
APPLICATION LIMITS
Annex B (informative) - Influence of scatter fraction
on the physical characteristics
Bibliography
Index of defined terms used in this standard
IEC 60627:2013 is applicable to anti-scatter grids used in medical diagnostic X-ray imaging equipment. Anti-Scatter Grids are used to reduce the incidence of scattered radiation, produced particularly in the body of the patient, upon the image reception area and thus to improve the contrast of the X-ray pattern. This International Standard specifies the definitions, determination and indication of characteristics of anti-scatter grids. In this standard only linear grids are considered. Since at present only focused grids are used in mammography, this standard is restricted to focused grids where mammographic anti-scatter grids are concerned. This standard is not intended to be applied for acceptance tests. This standard does not cover the homogeneity of performance over the area of a grid. This standard is intended to be applied for the determination of the characteristics of anti-scatter grids under test conditions. These conditions are not usually available at the site of the responsible organization. This third edition cancels and replaces the second edition published in 2001, and constitutes a technical revision. In this revision calcium tungstate phosphor fluorescent screens, which are no longer available, have been replaced by gadolinium oxysulphide (GOS) fluorescent screens. Further, a new quality parameter is introduced: the Image Improvement Factor or Q-factor, which better describes the properties of the anti-scatter grid, especially for digital detector applications. Further differences between this third edition and the previous second edition are:
- new instrumentation is prescribed for measurements of the transmission of primary radiation, the transmission of scattered radiation and the transmission of total radiation, because fluorescent screens made of calcium tungstate phosphors are outdated and are no longer available;
- the definition of the phantom used for measurements of the transmission of primary radiation, the transmission of scattered radiation and the transmission of total radiation is modified and references to IEC 61267 are omitted;
- and the radiation conditions used for the measurements have been adapted and are now the RQR and RQR-M conditions specified in IEC 61267:2005.
Committee |
TC 62/SC 62B
|
DevelopmentNote |
Supersedes IEC 61953 (01/2002) Stability date: 2018. (07/2013)
|
DocumentType |
Standard
|
Pages |
69
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
JIS Z 4910:2015 | Identical |
UNE-EN 60627:2002 | Identical |
NF EN 60627 : 2015 | Identical |
NBN EN 60627 : 2015 | Identical |
NEN EN IEC 60627 : 2015 | Identical |
PN EN 60627 : 2015 | Identical |
BS EN 60627:2015 | Identical |
CEI EN 60627 : 2016 | Identical |
EN 60627:2015 | Identical |
DIN EN 60627:2016-08 | Identical |
UNE-EN 60627:2015 | Identical |
BS 5913:1980 | Identical |
NEN 10627 : 1981 | Identical |
GOST R IEC 60627 : 2005 | Identical |
CEI 62-9 : 1ED 1998 | Identical |
DIN 6826:1980-09 | Corresponds |
PNE-FprEN 60627 | Identical |
UNE 20617:1981 | Identical |
17/30362279 DC : 0 | BS EN 61223-3-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-6: ACCEPTANCE AND CONSTANCY TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC TOMOSYNTHESIS MODE OF OPERATION OF MAMMOGRAPHIC X-RAY EQUIPMENT |
06/30107360 DC : 0 | IEC 60601-1-3 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD - RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT |
BS EN 61223-3-2:2008 | Evaluation and routine testing in medical imaging departments Acceptance tests. Imaging performance of mammographic X-ray equipment |
EN 61953 : 1998 | DIAGNOSTIC X-RAY IMAGING EQUIPMENT - CHARACTERISTICS OF MAMMOGRAPHIC ANTI-SCATTER GRIDS |
I.S. EN 60601-2-54:2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
BS EN 60601-2-54:2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
I.S. EN 60601-1-3:2008 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT |
EN 60601-1-3 : 2008 AMD 11 2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008/A1:2013) |
BS ISO 16142-1:2016 | Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards |
ISO 16142-1:2016 | Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards |
I.S. EN 61223-3-2:2008 | EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-2: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT |
IEC 61223-3-2:2007 | Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment |
UNE-EN 60601-2-54:2010 | Medical electrical equipment -- Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
PD IEC TR 60788:2004 | Medical electrical equipment. Glossary of defined terms |
14/30290166 DC : 0 | BS ISO 16142-1 - MEDICAL DEVICES - RECOGNIZED ESSENTIAL PRINCIPLES OF SAFETY AND PERFORMANCE OF MEDICAL DEVICES - PART 1: GENERAL ESSENTIAL PRINCIPLES AND ADDITIONAL SPECIFIC ESSENTIAL PRINCIPLES FOR ALL NON-IVD MEDICAL DEVICES AND GUIDANCE ON THE SELECTION OF STANDARDS |
08/30149952 DC : DRAFT MAY 2008 | BS EN 60601-2-54 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
17/30341818 DC : 0 | BS EN 60601-2-54 ED 1.0/A2 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
IEC 60601-2-54:2009+AMD1:2015 CSV | Medical electrical equipment - Part 2-54: Particular requirementsfor the basic safety and essential performance of X-ray equipmentfor radiography and radioscopy |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
BS EN 60601-1-3 : 2008 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008) |
IEC 61953:1997 | Diagnostic X-ray imaging equipment - Characteristics of mammographic anti-scatter grids |
BS EN 61953:1998 | Diagnostic X-ray imaging equipment. Characteristics of mammographic anti-scatter grids |
EN 61223-3-2:2008 | Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment |
EN 60601-2-54:2009/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-54: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR RADIOGRAPHY AND RADIOSCOPY |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
IEC 61267:2005 | Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.