IEC 60645-7:2009
Current
The latest, up-to-date edition.
Electroacoustics - Audiometric equipment - Part 7: Instruments for the measurement of auditory brainstem responses
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
29-04-2009
IEC 60645-7:2009 applies to instruments designed for the measurement of auditory evoked potentials from the inner ear, the auditory nerve and the brainstem, evoked by acoustic and/or vibratory stimuli of short duration. IEC 60645-7:2009 defines the characteristics to be specified by the manufacturer, specifies performance requirements for two types of instrument, screening and diagnostic, and specifies the functions to be provided on these types. The purpose of IEC 60645-7:2009 is to ensure that measurements made under comparable test conditions with different instruments complying with this standard will be consistent. IEC 60645-7:2009 is not intended to restrict development or incorporation of new features, nor to discourage innovative approaches. The application of electric stimuli for special purposes is beyond the scope of this standard.
DevelopmentNote |
Stability Date: 2020. (09/2017)
|
DocumentType |
Standard
|
Pages |
25
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NBN EN 60645-7 : 2010 | Identical |
NF EN 60645-7 : 2010 | Identical |
NEN EN IEC 60645-7 : 2010 | Identical |
I.S. EN 60645-7:2010 | Identical |
PN EN 60645-7 : NOV 2010 | Identical |
UNE-EN 60645-7:2010 | Identical |
BS EN 60645-7:2010 | Identical |
CEI EN 60645-7 : 2013 | Identical |
EN 60645-7:2010 | Identical |
DIN EN 60645-7:2010-08 | Identical |
IEC 60645-3:2007 | Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
IEC 60601-2-40:2016 | Medical electrical equipment - Part 2-40: Particular requirements for the basic safety and essential performance of electromyographs and evoked response equipment |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |