• IEC 60728-7-2:2003

    Current The latest, up-to-date edition.

    Cable networks for television signals, sound signals and interactive services - Part 7-2: Hybrid fibre coax outside plant status monitoring - Media access control (MAC) layer specification

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  08-10-2003

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Reference architecture forward and return channel
      specifications
    5 Media access control layer specification
      5.1 Overview
      5.2 MAC packet transport
      5.3 MAC packet structure
      5.4 MAC packet delimiters
      5.5 MAC protocol data units (PDUs)
    6 MAC protocol operation
      6.1 Non-volatile parameters
      6.2 Duplex capabilities
      6.3 Packet priorities
      6.4 Packet reception
      6.5 NE responses
      6.6 Message sequence numbers and transaction synchronization
      6.7 Solicited messages
      6.8 Autonomous (unsolicited) messages
      6.9 Return channel transmissions
      6.10 MAC state machines
    Annex A (informative) Operational details
      A.1 Introduction
      A.2 Time of day
      A.3 Firmware downloads
      A.4 NE addressing
      A.5 Alarm processing HMS MAC protocol
      A.6 Automatic channel discovery
      A.7 Auto-registration
      A.8 Configuration changes and SNMP trap generation

    Abstract - (Show below) - (Hide below)

    specifies requirements for The Hybrid Fibre Coax (HFC) Outside Plant (OSP) Media Access Control (MAC) Layer. This standard is part of the series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The HMS Media Access Control (MAC) layer specification describes the messaging and protocols implemented at the Data Link Layer (DLL), layer 2 in the 7 layer ISO-OSI reference model, that support reliable and efficient communications between HMS compliant transponders interfacing to managed OSP network elements (NEs) and a centralized head-end element (HE).

    General Product Information - (Show below) - (Hide below)

    Committee TC 100/TA 5
    Development Note Stability Date: 2026. (10/2012)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    CEI EN 60728-7-3 : 2010 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 7-3: HYBRID FIBRE COAX OUTSIDE PLANT STATUS MONITORING - POWER SUPPLY TO TRANSPONDER INTERFACE BUS (PSTIB)
    EN 60728-7-3:2009 Cable networks for television signals, sound signals and interactive services - Part 7-3: Hybrid fibre coax outside plant status monitoring - Power supply to transponder interface bus (PSTIB)
    IEC 60728-7-3:2009 Cable networks for television signals, sound signals and interactive services - Part 7-3: Hybrid fibre coax outside plant status monitoring - Power supply to transponder interface bus (PSTIB)
    BS EN 60728-7-3:2009 Cable networks for television signals, sound signals and interactive services Hybrid fibre coax outside plant status monitoring. Power supply to transponder interface bus (PSTIB)
    I.S. EN 60728-7-3:2009 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 7-3: HYBRID FIBRE COAX OUTSIDE PLANT STATUS MONITORING - POWER SUPPLY TO TRANSPONDER INTERFACE BUS (PSTIB)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective