IEC 60811-408:2012
Current
The latest, up-to-date edition.
Electric and optical fibre cables - Test methods for non-metallic materials - Part 408: Miscellaneous tests - Long-term stability test of polyethylene and polypropylene compounds
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
12-03-2012
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Annex A (normative) - Sample conditioning
Bibliography
IEC 60811-408:2012 gives the procedure to establish as to whether or not the quality of a cable's components will be satisfactory over the proposed life of a communication cable. IEC 60811-408:2012 cancels and replaces Annex A of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.
Committee |
TC 20
|
DevelopmentNote |
To be read in conjunction with IEC 60811-100. (03/2012) Supersedes IEC 60811-4-2. (05/2012) Stability Date: 2018. (11/2017)
|
DocumentType |
Standard
|
Pages |
21
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
JIS C 3660-408:2019 | Identical |
GOST IEC 60811-408 : 2015 | Identical |
NF EN 60811-408 : 2012 | Identical |
NEN EN IEC 60811-408 : 2012 | Identical |
PN EN 60811-408 : 2012 | Identical |
DIN EN 60811-408 : 2012 | Identical |
VDE 0473-811-408 : 2012 | Identical |
UNE-EN 60811-408:2012 | Identical |
BS EN 60811-408:2012 | Identical |
CEI EN 60811-408 : 2014 | Identical |
EN 60811-408:2012 | Identical |
I.S. EN 50290-2-23:2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
UNE-EN 50290-2-23:2014 | Communication cables - Part 2-23: Common design rules and construction - Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables |
BS EN 50290-2-23:2013 | Communication cables Common design rules and construction. Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables |
CEI EN 50290-2-23 : 2014 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
13/30281393 DC : 0 | BS EN 50290-2-23 - COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION |
PREN 50290-2-23 : DRAFT 2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION |
EN 50290-2-23:2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
ISO 188:2011 | Rubber, vulcanized or thermoplastic — Accelerated ageing and heat resistance tests |
IEC 60811-601:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the drop point of filling compounds |
IEC 60811-100:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General |
IEC 60811-410:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 410: Miscellaneous tests - Test method for copper-catalyzed oxidative degradation of polyolefin insulated conductors |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.