• Shopping Cart
    There are no items in your cart

IEC 60811-510:2012

Current

Current

The latest, up-to-date edition.

Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after thermal ageing in air

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French, Spanish, Castilian

Published date

13-03-2012

€20.79
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Bibliography

IEC 60811-510:2012 specifies the test method for a wrapping test after thermal ageing in air. This test method applies specifically to polyolefin insulation in communication cables. This test is intended for polyolefin insulations of unfilled cables and of dry cores for filled cables, where the insulation has a wall thickness of less than or equal to 0,8 mm. IEC 60811-510:2012 cancels and replaces Clause 10 of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.

This publication is to be read in conjunction with IEC 60811-100:2012.

Committee
TC 20
DevelopmentNote
To be read in conjunction with IEC 60811-100. (03/2012) Supersedes IEC 60811-4-1 and IEC 60811-4-2. (05/2012) Stability Date: 2020. (11/2017)
DocumentType
Standard
Pages
16
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

UNE-EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
UNE-EN 50290-2-33:2016 Communication cables - Part 2-33: Common design rules and construction - Polyethylene insulation compounds for multi element metallic cables for indoor installation (data cable)
CEI EN 50290-2-25 : 2014 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
CEI EN 50290-2-29 : 2002 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
CEI EN 50290-2-33 : 1ED 2017 COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION COMPOUNDS FOR MULTI ELEMENT METALLIC CABLES FOR INDOOR INSTALLATION (DATA CABLE)
I.S. EN 50290-2-33:2016 COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION COMPOUNDS FOR MULTI ELEMENT METALLIC CABLES FOR INDOOR INSTALLATION (DATA CABLE)
I.S. EN 50290-2-23:2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES
EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
EN 50290-2-25:2013 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
UNE-EN 50290-2-23:2014 Communication cables - Part 2-23: Common design rules and construction - Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables
BS EN 50290-2-23:2013 Communication cables Common design rules and construction. Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables
UNE-EN 50290-2-25:2014 Communication cables - Part 2-25: Common design rules and construction - Polypropylene insulation compounds
I.S. EN 50290-2-29:2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
BS EN 50290-2-33:2016 Communication cables Common design rules and construction. Polyethylene insulation compounds for multi element metallic cables for indoor installation (data cable)
13/30281390 DC : 0 BS EN 50290-2-25 - COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
16/30336762 DC : 0 BS EN 50290-2-29 - COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
BS EN 50290-2-25:2013 Communication cables Common design rules and construction. Polypropylene insulation compounds
13/30293736 DC : 0 BS EN 50290-2-33 - COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI ELEMENT METALLIC DATA CABLES FOR INDOOR APPLICATION
EN 50290-2-33:2016 Communication cables - Part 2-33: Common design rules and construction - Polyethylene insulation compounds for multi element metallic cables for indoor installation (data cable)
PREN 50290-2-33 : DRAFT 2013 COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI ELEMENT METALLIC DATA CABLES FOR INDOOR APPLICATION
CEI EN 50290-2-23 : 2014 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES
13/30281393 DC : 0 BS EN 50290-2-23 - COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION
I.S. EN 50290-2-25:2013 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
BS EN 50290-2-29:2016 Communication cables Common design rules and construction. Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
PREN 50290-2-29 : DRAFT 2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
PREN 50290-2-23 : DRAFT 2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION
PREN 50290-2-25 : DRAFT 2013 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
EN 50290-2-23:2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES

IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General