• IEC 60811-510:2012

    Current The latest, up-to-date edition.

    Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after thermal ageing in air

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, Spanish, Castilian

    Published date:  13-03-2012

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Test method
    5 Test report
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 60811-510:2012 specifies the test method for a wrapping test after thermal ageing in air. This test method applies specifically to polyolefin insulation in communication cables. This test is intended for polyolefin insulations of unfilled cables and of dry cores for filled cables, where the insulation has a wall thickness of less than or equal to 0,8 mm. IEC 60811-510:2012 cancels and replaces Clause 10 of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.

    This publication is to be read in conjunction with IEC 60811-100:2012.

    General Product Information - (Show below) - (Hide below)

    Committee TC 20
    Development Note To be read in conjunction with IEC 60811-100. (03/2012) Supersedes IEC 60811-4-1 and IEC 60811-4-2. (05/2012) Stability Date: 2020. (11/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
    UNE-EN 50290-2-33:2016 Communication cables - Part 2-33: Common design rules and construction - Polyethylene insulation compounds for multi element metallic cables for indoor installation (data cable)
    CEI EN 50290-2-25 : 2014 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
    CEI EN 50290-2-29 : 2002 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
    CEI EN 50290-2-33 : 1ED 2017 COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION COMPOUNDS FOR MULTI ELEMENT METALLIC CABLES FOR INDOOR INSTALLATION (DATA CABLE)
    I.S. EN 50290-2-33:2016 COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION COMPOUNDS FOR MULTI ELEMENT METALLIC CABLES FOR INDOOR INSTALLATION (DATA CABLE)
    I.S. EN 50290-2-23:2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES
    EN 50290-2-29:2016 Communication cables - Part 2-29: Common design rules and construction - Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
    EN 50290-2-25:2013 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
    UNE-EN 50290-2-23:2014 Communication cables - Part 2-23: Common design rules and construction - Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables
    BS EN 50290-2-23:2013 Communication cables Common design rules and construction. Polyethylene insulation for multi-pair cables used in access telecommunication networks: Outdoor cables
    UNE-EN 50290-2-25:2014 Communication cables - Part 2-25: Common design rules and construction - Polypropylene insulation compounds
    I.S. EN 50290-2-29:2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
    BS EN 50290-2-33:2016 Communication cables Common design rules and construction. Polyethylene insulation compounds for multi element metallic cables for indoor installation (data cable)
    13/30281390 DC : 0 BS EN 50290-2-25 - COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
    16/30336762 DC : 0 BS EN 50290-2-29 - COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
    BS EN 50290-2-25:2013 Communication cables Common design rules and construction. Polypropylene insulation compounds
    13/30293736 DC : 0 BS EN 50290-2-33 - COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI ELEMENT METALLIC DATA CABLES FOR INDOOR APPLICATION
    EN 50290-2-33:2016 Communication cables - Part 2-33: Common design rules and construction - Polyethylene insulation compounds for multi element metallic cables for indoor installation (data cable)
    PREN 50290-2-33 : DRAFT 2013 COMMUNICATION CABLES - PART 2-33: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI ELEMENT METALLIC DATA CABLES FOR INDOOR APPLICATION
    CEI EN 50290-2-23 : 2014 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES
    13/30281393 DC : 0 BS EN 50290-2-23 - COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION
    I.S. EN 50290-2-25:2013 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
    BS EN 50290-2-29:2016 Communication cables Common design rules and construction. Crosslinked polyethylene insulation compounds: instrumentation, control and field bus cables
    PREN 50290-2-29 : DRAFT 2016 COMMUNICATION CABLES - PART 2-29: COMMON DESIGN RULES AND CONSTRUCTION - CROSSLINKED POLYETHYLENE INSULATION COMPOUNDS: INSTRUMENTATION, CONTROL AND FIELD BUS CABLES
    PREN 50290-2-23 : DRAFT 2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - PE INSULATION
    PREN 50290-2-25 : DRAFT 2013 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
    EN 50290-2-23:2013 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective