IEC 60846:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Radiation protection instrumentation - Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation
Hardcopy , PDF
English - French
11-06-2002
07-04-2009
FOREWORD
1 Scope and object
2 Normative references
3 Terminology
3.1 General
3.2 Definitions
3.3 Test nomenclature
3.4 Quantities and units
4 General characteristics of ambient and directional dose
equivalent (rate) meters
4.1 General
4.1.1 Indication
4.1.2 Read-out
4.1.3 Dose equivalent (rate) meter labels and markings
4.1.4 Dose equivalent and dose equivalent rate range
4.1.5 Effective range of measurement
4.1.6 Minimum range of measurement
4.1.7 Alarm levels
4.1.8 Additional indication
4.1.9 Failure operation of indication
4.1.10 Ease of decontamination
4.2 Classification of the performance characteristics
4.3 General test procedures
4.3.1 Nature of tests
4.3.2 Reference conditions and standard test conditions
4.3.3 Rated range of an influence quantity
4.3.4 Minimum rated range of influence quantity
4.3.5 Position of dose equivalent (rate) meter for
purposes of tests
4.3.6 Low dose equivalent rates
4.3.7 Statistical fluctuations
4.3.8 Production of reference radiation
4.3.9 Reference photon radiation
4.3.10 Reference beta radiation
4.3.11 Determination of dose equivalent (rate) at point
of test
5 Radiation characteristics - Directional dose equivalent (rate)
meters
5.1 Relative intrinsic error
5.1.1 Requirements
5.1.2 Test method
5.1.3 Requirements on the accuracy of alarm
of dose equivalent (rate) monitors
5.1.4 Test method
5.2 Variation of response with beta radiation energy and
angle of incidence
5.2.1 Requirements
5.2.2 Test method
5.3 Variation of response with photon radiation energy and
angle of incidence
5.3.1 Requirements
5.3.2 Test method
5.4 Overload characteristics
5.4.1 Requirements
5.4.2 Test method
5.5 Response to neutron radiation
5.5.1 Requirements
5.5.2 Test method
5.6 Response to pulsed ionizing radiation fields
5.6.1 Requirements
5.6.2 Test method
5.7 Statistical fluctuations
5.7.1 Requirements
5.7.2 Test method
5.8 Response time
5.8.1 Requirements
5.8.2 Test method
5.9 Interrelation between response time and statistical
fluctuations
6 Radiation characteristics - ambient dose equivalent (rate)
meters
6.1 Relative intrinsic error
6.1.1 Requirements
6.1.2 Test method
6.1.3 Requirements on the accuracy of alarm to set value
6.1.4 Test method
6.2 Variation of response with photon radiation energy and
angle of incidence
6.2.1 Requirements
6.2.2 Test method
6.3 Overload characteristics
6.4 Response to neutron radiation
6.5 Response to pulsed ionizing radiation fields
6.6 Statistical fluctuations
6.7 Response time
6.8 Interrelation between response time and statistical
fluctuations
7 Electrical characteristics of directional and ambient dose
equivalent (rate) meters
7.1 Stability of zero indication with time
7.1.1 Requirements
7.1.2 Test method
7.2 Stability of zero indication with variation of temperature
7.2.1 Requirements
7.2.2 Test method
7.3 Warm-up time
7.3.1 Requirements
7.3.2 Test method
7.4 Power supplies - battery operation
7.4.1 General
7.4.2 Requirements - primary batteries (non-rechargeable)
7.4.3 Requirements - secondary batteries (rechargeable)
7.4.4 Test method
7.5 Power supplies - mains operation
7.5.1 Requirements
7.5.2 Test method
8 Mechanical characteristics of directional and ambient dose
equivalent (rate) meters
8.1 Mechanical shock during operation
8.2 Orientation of dose equivalent (rate) meter (geotropism)
8.2.1 Requirements
8.2.2 Test method
9 Environmental characteristics, performance requirements and
tests
9.1 Ambient temperature influence
9.1.1 Requirements
9.1.2 Test method
9.2 Relative humidity
9.2.1 Requirements
9.2.2 Test method
9.3 Atmospheric pressure
9.3.1 Requirements
9.3.2 Test method
9.4 Sealing against moisture
9.5 Storage and transport
9.6 Electromagnetic compatibility
9.6.1 General
9.6.2 Emission of electromagnetic radiation
9.6.3 Electrostatic discharge
9.6.4 Radiated electromagnetic fields
9.6.5 Conducted disturbances induced by fast transients
or bursts
9.6.6 Conducted disturbances induced by surges
9.6.7 Conducted disturbances induced by radio-frequencies
9.6.8 50 Hz/60 Hz magnetic field
9.6.9 Voltage dips and short interruptions
9.7 Vibration and mechanical shock
9.7.1 Requirements
9.7.2 Vibration
9.7.3 Mechanical shock
10 Summary of characteristics
11 Documentation
11.1 Certificate
11.2 Operation and maintenance manual
Annex A (normative) Statistical fluctuations
Bibliography
Tables
Specifies the design requirements and the performance characteristics of dose equivalent (rate) meters intended for the determination of ambient dose equivalent (rate) and directional dose equivalent (rate) as defined in ICRU Report 47.
| Committee |
TC 45/SC 45B
|
| DocumentType |
Standard
|
| Pages |
97
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| NF EN 60846 : 2005 | Identical |
| NEN IEC 60846 : 2002 | Identical |
| NEN EN IEC 60846 : 2004 | Identical |
| I.S. EN 60846:2004 | Identical |
| BS EN 60846:2004 | Identical |
| CEI 45-48 : 1ED 1997 | Identical |
| EN 60846:2004 | Identical |
| DIN EN 60846 : 2005 | Identical |
| UNE-EN 60846:2009 | Identical |
| NEN 10846 : 1990 | Identical |
| UNE 21744:1996 | Identical |