• Shopping Cart
    There are no items in your cart

IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

12-09-2013

Superseded date

21-11-2024

Superseded by

IEC 61008-1:2024

€1,408.77
Excluding VAT
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Characteristics of RCCBs
6 Marking and other product information
7 Standard conditions for operation in service and
  for installation
8 Requirements for construction and operation
9 Tests
Annex A (normative) - Test sequence and number of
        samples to be submitted for certification
        purposes
Annex B (normative) - Determination of clearances and
        creepage distances
Annex C (normative) - Arrangement for the detection of
        the emission of ionized gases during short-circuit
        tests
Annex D (normative) - Routine tests
Annex E (informative) - Void
Annex IA (informative) - Methods for determination of
         short-circuit power-factor
Annex IB (informative) - Glossary of symbols
Annex IC (informative) - Examples of terminal designs
Annex ID (informative) - Correspondence between ISO
         and AWG copper conductors
Annex IE (informative) - Follow-up testing program for
         RCCBs
Annex IF (informative) - SCPDs for short-circuit tests
Annex J (normative) - Particular requirements for
        RCCBs with screwless type terminals
        for external copper conductors
Annex K (normative) - Particular requirements
        for RCCBs with flat quick-connect
        terminations
Annex L (normative) - Specific requirements
        for RCCBs with screw-type terminals
        for external untreated aluminium
        conductors and with aluminium
        screw-type terminals for use with
        copper or with aluminium conductors
Bibliography

IEC 61008-1:2010+A1:2012+A2:2013 applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. This third edition cancels and replaces the second edition published in 1996, amendment 1 (2002) and amendment 2 (2006). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- complete revision of EMC sequences, including the new test T.2.6 already approved in IEC 61543;
- clarification of RCDs current/time characteristics reported in Tables 1 and 2;
- revision of test procedure for IΔn between 5 A and 200 A;
- testing procedure regarding the 6mA d.c. current superimposed to the fault current;
- improvement highlighting RCDs with multiple sensitivity;
- tests for the use of RCCBs in IT systems.
This consolidated version consists of the third edition (2010), its amendment 1 (2012), its amendment 2 (2013) and the corrigendum of January 2014. Therefore, no need to order amendments in addition to this publication.

Committee
TC 23/SC 23E
DevelopmentNote
Also available in CD-ROM format. (09/2013) Stability date: 2018. (11/2017)
DocumentType
Standard
Pages
680
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition
€1,408.77
Excluding VAT