• IEC 61010-2-051:2015

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  13-02-2019

    Language(s):  English - French

    Published date:  10-03-2015

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope and object
    2 Normative references
    3 Terms and definitions
    4 Tests
    5 Marking and documentation
    6 Protection against electric shock
    7 Protection against mechanical HAZARDS
    8 Resistance to mechanical stresses
    9 Protection against the spread of fire
    10 Equipment temperature limits and resistance to heat
    11 Protection against HAZARDS from fluids
    12 Protection against radiation, including laser sources,
       and against sonic and ultrasonic pressure
    13 Protection against liberated gases and substances,
       explosion and implosion
    14 Components and subassemblies
    15 Protection by interlocks
    16 HAZARDS resulting from application
    17 RISK Assessment
    Annexes
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 61010-2-051:2015 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices may contain heating elements. It has the status of a group safety publication in accordance with IEC Guide 104. This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision and includes the following change from the second edition:
    - exclusion of equipment, whose size and weight make unintentional movement unlikely, from the drop test in Clause 8,
    - added requirement for interlock systems containing electric/electronic or programmable components to Clause 15,
    - notes have been re-phrased according to ISO/IEC Directives.

    This publication is to be read in conjunction with IEC 61010-1:2010.

    General Product Information - (Show below) - (Hide below)

    Committee TC 66
    Development Note Stability date: 2018. (03/2015)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    CSA Z15190 : 2005 : R2010 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY
    ISO 15190:2003 Medical laboratories Requirements for safety
    BS ISO 15190:2003 Medical laboratories. Requirements for safety
    CSA Z15190 : 2005 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY
    CSA Z15190 : 2005 : R2015 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61010-2-010:2014 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of materials
    IEC 62061:2005+AMD1:2012+AMD2:2015 CSV Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective