• Shopping Cart
    There are no items in your cart

IEC 61036:1996+AMD1:2000 CSV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Alternating current static watt-hour meters for active energy (classes 1 and 2)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

29-09-2000

Superseded date

28-01-2003

€529.58
Excluding VAT
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
    3.1 General definitions
    3.2 Definitions related to the functional
          elements
    3.3 Definitions of mechanical elements
    3.4 Definitions of insulations
    3.5 Definitions of meter quantities
    3.6 Definitions of influence quantities
    3.7 Definition of tests
4 Requirements
    4.1 Standard electrical values
    4.2 Mechanical requirements
    4.3 Climatic Conditions
    4.4 Electrical requirements
    4.5 Electromagnetic compatibility (EMC)
    4.6 Accuracy requirements
5 Tests and test conditions
    5.1 General testing procedures
    5.2 Tests of mechanical requirements
    5.3 Tests of climatic influences
    5.4 Tests of electrical requirements
    5.5 Tests for electromagnetic compatibility (EMC)
    5.6 Tests of accuracy requirements
Tables
1 Standard reference voltages
2 Standard reference currents
3a Clearances and creepage distances for insulating
    encased meter of protective class 1
3b Clearances and creepage distances for insulating
    encased meter of protective class II
4 Voltage marking
5 Temperature range
6 Relative humidity
7 Power consumption in voltage circuits including
    the power supply
8 Power consumption in voltage circuits including
    power supply
9 Voltage range
10 Variations due to short-time overcurrents
11 Variations due to self-heating
12 Change of error due to earth fault
13 Percentage error (single-phase meters and
    polyphase meters with balanced loads)
14 Percentage error limits (polyphase meters carrying
    a single-phase load, but with balanced polyphase
    voltages applied to voltage circuits)
15 Influence quantities
16 Temperature coefficient
17 Starting current
18 AC voltage tests
19 Voltage and current balance
20 Reference conditions
21 Interpretation of test results
Annexes
A Relationship between ambient air temaperature
    and relative humidity
B Test circuit diagram for d.c., even harmonics,
    odd harmonics and sub-harmonics
C Voltage waveform for the tests of the effect of
    voltage dips and short interruptions
D Electromagnet for testing the influence of externally
    produced magnetic fields
E Test schedule
F Test circuit diagram for the test of immunity
    to earth fault

Applies only to newly manufactured indoor or outdoor static watt-hour meters of accuracy classes 1 and 2, for the measurement of alternating-current electrical active energy of a frequency in the range 45 Hz to 65 Hz and to their type tests only. Does not apply to watt-hour meters where the voltage across the connection terminals exceeds 600 V, portable meters, data interfaces to the register of the meter. Acceptance tests are partially given in IEC 60514.

Committee
TC 13
DevelopmentNote
Also numbered as BS EN 61036 (08/2002)
DocumentType
Standard
Pages
105
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
€529.58
Excluding VAT