IEC 61076-3-115:2009
Current
The latest, up-to-date edition.
Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type
Hardcopy , PDF
English - French
17-06-2009
FOREWORD
INTRODUCTION
1 General data
1.1 Scope and object
1.2 Normative references
2 Terms and definitions
3 Dimensional information
3.1 Common features
3.2 General
3.3 Contact arrangement of all connector types
3.4 IP65 and IP67 sealing
3.5 Industrial IEC 60603-7 variant 12 - Push-pull
coupling
3.5.1 Industrial IEC 60603-7 variant 12, fixed
connectors
3.5.2 Industrial IEC 60603-7 variant 12, free
connectors
3.6 Termination and mounting information
3.6.1 General
3.6.2 Mounting information for variant 12, fixed
connector
3.7 Cap for fixed connector
3.8 Cap for free connector
4 Gauges
4.1 Connectors, IEC 60603-7 interface
5 Characteristics
5.1 Climatic category
5.2 Electrical
5.2.1 Clearance and creepage distances
5.2.2 Voltage proof
5.2.3 Current derating diagram
5.2.4 Mating cycles with power applied
5.2.5 Initial contact resistance
5.2.6 Input-to-output resistance
5.2.7 Resistance unbalance
5.2.8 Initial insulation resistance
5.3 Transmission characteristics
5.3.1 General
5.3.2 Mechanical operation
5.3.3 Effectiveness of connector coupling devices,
transversal
5.3.4 Effectiveness of connector coupling devices
5.3.5 Separation and engagement forces
6 Test schedule
6.1 General
6.2 Test procedures and measuring methods
6.3 Preconditioning
6.4 Wiring and mounting of specimens
6.4.1 Wiring
6.4.2 Mounting
6.5 Arrangement for contact resistance test
6.6 Arrangement for dynamic stress tests (test phase
AP2)
6.7 Basic (minimum) test schedule
6.8 Full test schedule
6.8.1 Test preliminary group P
6.8.2 Test group P
6.8.3 Test group AP
6.8.4 Test group BP
6.8.5 Test group CP
6.8.6 Test group DP
6.8.7 Test group EP
IEC 61076-3-115:2009 covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-5, and IEC 60603-7-7 to IP65 and IP67 ratings, according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this standard and a variety of different mounting configurations and termination types which are detailed in IEC 60603-7.
| Committee |
TC 48/SC 48B
|
| DevelopmentNote |
Supersedes IEC PAS 61076-3-115. (06/2009) Stability Date: 2017. (10/2012)
|
| DocumentType |
Standard
|
| Pages |
49
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NBN EN 61076-3-115 : 2010 | Identical |
| NEN EN IEC 61076-3-115 : 2010 | Identical |
| I.S. EN 61076-3-115:2010 | Identical |
| PN EN 61076-3-115 : 2010 | Identical |
| VDE 0687-76-3-115:2011-06 | Identical |
| DIN EN 61076-3-115:2011-06 | Identical |
| CEI EN 61076-3-115 : 2012 | Identical |
| EN 61076-3-115:2010 | Identical |
| BS EN 61076-3-115:2010 | Identical |
| UNE-EN 61076-3-115:2010 | Identical |