• IEC 61223-2-5:1994

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Evaluation and routine testing in medical imaging departments - Part 2-5: Constancy tests - Image display devices

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  31-12-2021

    Language(s):  English - French, Spanish, Castilian

    Published date:  30-03-1994

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope and object
       1.1 Scope
       1.2 Object
    2 Normative references
    3 Terminology
       3.1 Degree of requirements
       3.2 Use of terms
       3.3 Definitions
    4 General aspects of CONSTANCY TESTS
       4.1 General conditions affecting test procedures
       4.2 Establishment of BASELINE VALUES
       4.3 Frequency of CONSTANCY TESTS
       4.4 Identification of equipment, instrumentation
            and test conditions
       4.5 Measured functional parameters
    5 Test methods
       5.1 Summary
       5.2 Test equipment
       5.3 Test procedure
       5.4 Data evaluation
       5.5 Criteria to be applied
       5.6 Test report
       5.7 Action to be taken
       5.8 Frequency of testing
    6 Statement of compliance
    Figures
    Annexes
    A Terminology - Index of terms
    B Example of a form for the standardized test report
    C Guidance on action to be taken
    D Rationale
    E Bibliography - Reference test pattern
    F IMAGE DISPLAY DEVICES in workstations: Environmental
       conditions

    Abstract - (Show below) - (Hide below)

    Applies to image display devices as used in diagnostic imaging systems. Describes a method to check, in terms of functional parameters the constancy of the quality of images reproduced by image display devices.

    General Product Information - (Show below) - (Hide below)

    Development Note Also numbered as BS EN 61223-2.5 and BS 7725-2.5(1995) (11/2005)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS IEC 61223-2.10 : 2000 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-10 - CONSTANCY TESTS - X-RAY EQUIPMENT FOR MAMMOGRAPHY
    CEI 62-112 : 2001 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2: CONSTANCY TESTS - EQUIPMENT FOR INTRA-ORAL DENTAL RADIOGRAPHY EXCLUDING DENTAL PANORAMIC EQUIPMENT
    17/30362279 DC : 0 BS EN 61223-3-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-6: ACCEPTANCE AND CONSTANCY TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC TOMOSYNTHESIS MODE OF OPERATION OF MAMMOGRAPHIC X-RAY EQUIPMENT
    BS IEC 61223-2.7 : 1999 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-7: CONSTANCY TESTS - EQUIPMENT FOR INTRA-ORAL DENTAL RADIOGRAPHY EXCLUDING DENTAL PANORAMIC EQUIPMENT
    BS EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments Acceptance tests. Imaging performance of mammographic X-ray equipment
    IEC 61223-2-10:1999 Evaluation and routine testing in medical imaging departments - Part 2-10: Constancy tests - X-ray equipment for mammography
    CEI 62-113 : 2001 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2: CONSTANCY TESTS - EQUIPMENT FOR INDIRECT RADIOSCOPY AND INDIRECT
    I.S. EN 61223-2-6:2007 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-6: CONSTANCY TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
    EN 61223-3-3:1996 Evaluation and routine testing in medical imaging departments - Part 3-3: Acceptance tests - Imaging performance of X-ray equipment for digital subtraction angiography (DSA)
    13/30246074 DC : DRAFT JAN 2014 BS ISO 12646 - GRAPHIC TECHNOLOGY - DISPLAYS FOR COLOUR PROOFING - CHARACTERISTICS AND VIEWING CONDITIONS
    BS IEC 61223-2.9 : 1999 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-9 - CONSTANCY TESTS - EQUIPMENT FOR INDIRECT RADIOSCOPY AND INDIRECT RADIOGRAPHY
    IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
    IEC 61223-3-3:1996 Evaluation and routine testing in medical imaging departments -Part 3-3: Acceptance tests - Imaging performance of X-ray equipmentfor digital subtraction angiography (DSA)
    14/30246074 DC : 0 BS ISO 12646 - GRAPHIC TECHNOLOGY - DISPLAYS FOR COLOUR PROOFING - CHARACTERISTICS AND VIEWING CONDITIONS
    02/122175 DC : DRAFT MAY 2002 BS ISO 12646 - GRAPHIC TECHNOLOGY - DISPLAYS FOR COLOUR PROOFING - CHARACTERISTICS AND VIEWING CONDITIONS
    BS ISO 12646:2015 Graphic technology. Displays for colour proofing. Characteristics
    I.S. EN 61223-3-2:2008 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-2: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT
    IEC 61223-3-2:2007 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment
    BS EN 62563-1:2010 Medical electrical equipment. Medical image display systems Evaluation methods
    PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
    CEI 62-114 : 2001 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2: CONSTANCY TESTS - X-RAY EQUIPMENT FOR MAMMOGRAPHY
    IEC 61223-2-9:1999 Evaluation and routine testing in medical imaging departments - Part 2-9: Constancy tests - Equipment for indirect radioscopy and indirect radiography
    IEC 61223-2-7:1999 Evaluation and routine testing in medical imaging departments - Part 2-7: Constancy tests - Equipment for intra-oral dental radiography excluding dental panoramic equipment
    I.S. EN 62563-1:2010 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL IMAGE DISPLAY SYSTEMS - PART 1: EVALUATION METHODS
    EN 62563-1:2010/A1:2016 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL IMAGE DISPLAY SYSTEMS - PART 1: EVALUATION METHODS (IEC 62563-1:2009/A1:2016)
    IEC 61223-2-4:1994 Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras
    IEC 61223-2-6:2006 Evaluation and routine testing in medical imaging departments ­ - Part 2­-6: Constancy tests ­ imaging performance of computed tomography X-ray equipment
    IEC 62563-1:2009+AMD1:2016 CSV Medical electrical equipment - Medical image display systems - Part1: Evaluation methods
    BS EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments Constancy tests. Imaging performance of computed tomography X-ray equipment
    ISO 12646:2015 Graphic technology — Displays for colour proofing — Characteristics
    EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments - Part 2-6: Constancy tests - Imaging performance of computed tomography X-ray equipment
    EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
    IEC 61223-2-4:1994 Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective