IEC 61241-1:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
13-11-2008
English - French, Spanish, Castilian
10-05-2004
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Construction
5 Practice A and practice B
6 Supplementary requirements for electrical apparatus protected
by enclosures for practice A for use in zones 20, 21 and 22
7 Supplementary requirements for electrical apparatus protected
by enclosures for practice B for use in zone 20 or 21
7.1 Joints
7.1.1 Plain joints
7.1.2 Spigotted joints
7.1.3 Gasketed joints
7.2 Operating rods, spindles or shafts
7.2.1 General
7.2.2 Running contact seals
7.2.3 Power shafts
7.2.4 Operating rods
7.3 Clearance of bolts
8 Verification and tests
8.1 General
8.2 Type tests
8.2.1 Tests for dust exclusion by enclosures
8.2.2 Thermal tests
9 Marking
Bibliography
Figures
Tables
Applicable to electrical apparatus protected by enclosures and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. Specifies requirements for design, construction and testing of electrical apparatus.The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and on other surfaces which could be in contact with dust and on the restriction of dust ingress into the enclosure by the use of "dust-tight" or "dust-protected" enclosures.
DevelopmentNote |
Together with IEC 61241-0 supersedes IEC 61241-1-1. (07/2004)
|
DocumentType |
Standard
|
Pages |
29
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 61241-1 : 2004 | Identical |
NEN EN IEC 61241-1 : 2004 C11 2007 | Identical |
I.S. EN 61241-1:2004 | Identical |
PN EN 61241-1 : 2005 AC 2007 | Identical |
SAC GB 12476-5 : 2013 | Identical |
AS/NZS 61241.1:2005 | Identical |
VDE 0170-15-1 : 2014 | Identical |
UNE-EN 61241-1:2005 | Identical |
BIS IS/IEC 61241-1 : 2004 | Identical |
BS EN 61241-1:2004 | Identical |
CEI EN 61241-1 : 2006 | Identical |
EN 61241-1:2004/corrigendum Dec. 2006 | Identical |
AS/NZS 61241.18:2005 | Identical |
I.S. EN 61241-14:2004 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION |
11/30248849 DC : 0 | BS EN 50050-3:2011 - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 3: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE FLOCK |
BS EN 61241-0:2006 | Electrical apparatus for use in the presence of combustible dust General requirements |
BS EN 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
S.R. CLC/TS 60034-31:2011 | ROTATING ELECTRICAL MACHINES - PART 31: SELECTION OF ENERGY-EFFICIENT MOTORS INCLUDING VARIABLE SPEED APPLICATIONS - APPLICATION GUIDE |
I.S. EN 61241-11:2007 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 11: PROTECTION BY INTRINSIC SAFETY "ID" |
NF EN 50050 : 2007 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT |
BS EN 13463-1:2009 | Non-electrical equipment for use in potentially explosive atmospheres Basic method and requirements |
UNE-EN 1127-1:2012 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
BS EN 61241-18:2004 | Electrical apparatus for use in the presence of combustible dust Protection by encapsulation \'mD\' |
EN 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
EN 13463-1:2009 | Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements |
EN 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
EN 50050:2006 | Electrical apparatus for potentially explosive atmospheres - Electrostatic hand-held spraying equipment |
BS EN 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust Selection and installation |
10/30230365 DC : 0 | BS EN 50050-2 - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER |
DD IEC TS 60034-31 : DRAFT JULY 2010 | ROTATING ELECTRICAL MACHINES - PART 31: SELECTION OF ENERGY-EFFICIENT MOTORS INCLUDING VARIABLE SPEED APPLICATIONS - APPLICATION GUIDE |
12/30270980 DC : 0 | BS EN 1127-2 - EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
IEC TS 60034-31:2010 | Rotating electrical machines - Part 31: Selection of energy-efficient motors including variable speed applications - Application guide |
I.S. EN 1127-1:2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
CLC/TS 60034-31:2011 | Rotating electrical machines - Part 31: Selection of energy-efficient motors including variable speed applications - Application guide |
DIN EN 1127-1:2011-10 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
DIN EN 13463-1:2009-07 | NON-ELECTRICAL EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES - PART 1: BASIC METHOD AND REQUIREMENTS |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
VDI 2263 Blatt 7:2010-07 | Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in spraying and drying integrated equipment |
I.S. EN 13463-1:2009 | NON-ELECTRICAL EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES - PART 1: BASIC METHOD AND REQUIREMENTS |
I.S. EN 50050:2006 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT |
BS EN 1127-1:2019 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
EEMUA 186 : 2016 | A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES |
UNE-EN 60079-14:2016 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
IEC 61241-17:2005 | Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines) |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
UNI EN 13463-1 : 2009 | NON-ELECTRICAL EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES - PART 1: BASIC METHOD AND REQUIREMENTS |
08/30183108 DC : DRAFT MAY 2008 | BS IEC/TS 60034-31 - ROTATING ELECTRICAL MACHINES - PART 31: GUIDE FOR THE SELECTION AND APPLICATION OF ENERGY-EFFICIENT MOTORS INCLUDING VARIABLE-SPEED APPLICATIONS |
CSA C22.4 PACKAGE : 2009 | CONSISTS OF C22.4 NO. 1-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE AND C22.4 NO. 2-09, OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE - SAFETY MANAGEMENT SYSTEM REQUIREMENTS |
BS EN 61241-11:2006 | Electrical apparatus for use in the presence of combustible dust Protection by intrinsic safety \'iD\' |
PREN 50050-3 : DRAFT 2011 | ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 3: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE FLOCK |
PREN 50050-2 : DRAFT 2011 | ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER |
DD CLC/TS 60034-31:2011 | Rotating electrical machines Selection of energy-efficient motors including variable speed applications. Application guide |
11/30248845 DC : 0 | BS EN 50050-2:2011 - ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - PART 2: HAND-HELD SPRAYING EQUIPMENT FOR IGNITABLE COATING POWDER |
UNI EN 1127-1 : 2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
I.S. EN 61241-17:2005 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES) |
BS EN 50050:2006 | Electrical apparatus for potentially explosive atmospheres. Electrostatic hand-held spraying equipment |
I.S. EN 61241-0:2006 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 0: GENERAL REQUIREMENTS |
IEC 61241-11:2005 | Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety 'iD' |
05/30134569 DC : DRAFT JUN 2005 | IEC 60079-0. ED. 5.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS |
IEC 61241-18:2004 | Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation 'mD' |
UNE-EN 13463-1:2011 | Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements |
EN 61241-18:2004 | Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation "mD" |
CSA C22.4 No. 1 : 2009(R2018) | OBJECTIVE-BASED INDUSTRIAL ELECTRICAL CODE |
I.S. EN 60079-14:2014 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION |
PREN 1127-2 : DRAFT 2012 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 2: BASIC CONCEPTS AND METHODOLOGY FOR MINING |
BS EN 1127-1:2011 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
12/30269297 DC : 0 | BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION |
EN 61241-11:2006 | Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety "iD" |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
EN 61241-0:2006 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
ISO 4225:1994 | Air quality General aspects Vocabulary |
IEC 61241-0:2004 | Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements |
IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60093:1980 | Methods of test for volume resistivity and surface resistivity of solid electrical insulating materials |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
ISO 178:2010 | Plastics Determination of flexural properties |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
IEC 61241-10:2004 | Electrical apparatus for use in the presence of combustible dust - Part 10: Classification of areas where combustible dusts are or may be present |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.