IEC 61266:1994
Current
The latest, up-to-date edition.
Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
15-12-1994
FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 Definitions
4 List of symbols
5 Configuration
6 Performance
6.1 Acoustic working frequency
7 Safety
8 Tests
8.1 Acoustic working frequency
8.2 Output power
8.3 Spatial-peak temporal-peak acoustic pressure
8.4 Effective area of the ultrasonic transducer
active element
8.5 Overall sensitivity
9 Preferred method for reporting performance of
existing equipment
10 Specifications for labelling
11 Sampling
Figures
Annexes
A Choice of target and determination of target
plane-wave reflection loss
B Typical test equipment and test procedures
C Determination of the two-way insertion loss of
acoustic attenuators
D Rationale
E Bibliography
Is applicable to ultrasonic Doppler foetal heartbeat detectors which generate a single ultrasound beam and consist of a hand-held probe which is applied to the maternal abdomen to obtain information on foetal heart activity by means of the Doppler method using continuous wave (c.w) or quasi-continuous wave ultrasound.Establishes - methods of measurement of performances - requirements for the performance and the - reporting of performance
DevelopmentNote |
Also numbered as BS EN 61266. (09/2005) Stability Date: 2020. (09/2017)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 61266 : 1996 | Identical |
NEN 11266 : 1995 | Identical |
I.S. EN 61266:1997 | Identical |
PN EN 61266 : 2002 | Identical |
AS/NZS 4374:1996 | Identical |
SN EN 61266 : 1995 | Identical |
UNE-EN 61266:1996 | Identical |
CEI EN 61266 : 1998 | Identical |
EN 61266:1995 | Corresponds |
DIN EN 61266:1996-06 | Identical |
EN 61266:1995 | Identical |
VDE 0418-3-31 : 1999 | ELECTRICITY METERING EQUIPMENT (A.C.) - PARTICULAR REQUIREMENTS - PART 31: PULSE OUTPUT DEVICES FOR ELECTROMECHANICAL AND ELECTRONIC METERS (TWO WIRES ONLY) |
DIN EN 62053-31 : 1999 | ELECTRICITY METERING EQUIPMENT (A.C.) - PARTICULAR REQUIREMENTS - PART 31: PULSE OUTPUT DEVICES FOR ELECTROMECHANICAL AND ELECTRONIC METERS (TWO WIRES ONLY) |
99/200863 DC : DRAFT JAN 1999 | IEC 61895. TS. ED. 1 - ULTRASONICS - PULSED DOPPLER DIAGNOSTIC SYSTEMS - TEST PROCEDURES TO DETERMINE PERFORMANCE |
IEC 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC TR 60854:1986 | Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment |
IEC 61101:1991 | The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0.5 MHz to 15 MHz |
IEC 61157:2007+AMD1:2013 CSV | Standard means for the reporting of the acoustic output of medicaldiagnostic ultrasonic equipment |
IEC 60866:1987 | Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz |