FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Interface characteristics
6 Information
7 Service conditions
8 Constructional requirements
9 Performance requirements
10 Design verification
11 Routine verification
Annexes
Annex AA (informative) - Items subject to agreement
         between the ASSEMBLY manufacturer and the
         user
Bibliography

IEC 61439-3:2012 defines the specific requirements for distribution boards intended to be operated by ordinary persons (DBO). DBOs have the following criteria:
- intended to be operated by ordinary persons (e.g. switching operations and replacing fuse-links), e.g. in domestic (household) applications;
- outgoing circuits contain protective devices, intended to be operated by ordinary persons, complying e.g. with IEC 60898-1, IEC 61008, IEC 61009, IEC 62423 and IEC 60269-3;
- rated voltage to earth does not exceed 300 V a.c.;
- rated current (Inc) of the outgoing circuits does not exceed 125 A and the rated current (InA) of the DBO does not exceed 250 A;
- intended for the distribution of electrical energy;
- enclosed, stationary;
- for indoor or outdoor use.
This first edition cancels and replaces the first edition of IEC 60439-3 (1990), Amendment 1 (1993) and Amendment 2 (2001). It constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60439-3 (including the amendments):
- alignment with IEC 61439-1:2011.

This publication is to be read in conjunction with IEC 61439-1:2011. The contents of the corrigenda of September 2013 and March 2019 have been included in this copy.

DevelopmentNote
Supersedes IEC 60439-3. To be read in conjunction with IEC 61439-1. (02/2012) Stability Date: 2019. (09/2017)
DocumentType
Standard
Pages
41
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

IEC TS 62257-9-3:2016 Recommendations for renewable energy and hybrid systems for rural electrification - Part 9-3: Integrated systems - User interface
IEC 62933-2-1:2017 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
I.S. HD 62640:2015 RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES
PD IEC/TR 61439-0:2013 Low-voltage switchgear and controlgear assemblies Guidance to specifying assemblies
17/30354643 DC : 0 BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
IEC TR 61439-0:2013 Low-voltage switchgear and controlgear assemblies - Part 0: Guidance to specifying assemblies
PD IEC/TS 62257-9-3:2016 Recommendations for renewable energy and hybrid systems for rural electrification Integrated systems. User interface
EN IEC 62933-2-1:2018 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
I.S. EN IEC 62933-2-1:2018 ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
HD 62640:2015/A11:2016 RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED)
UNE-HD 62640:2016 Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses
IEC TS 61439-7:2014 Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicles charging stations
PRHD 62640 : DRAFT 2014 RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED)

IEC 62423:2009 Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
IEC 60898-1:2015 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
IEC 60947-2:2016 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.