• IEC 61582:2004

    Current The latest, up-to-date edition.

    Radiation protection instrumentation - In vivo counters - Classification, general requirements and test procedures for portable, transportable and installed equipment

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French

    Published date:  08-01-2004

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope and object
    2 Normative references
       2.1 International standards
       2.2 Other International references
    3 Terms and definitions
    4 Classification
       4.1 General classification
       4.2 Energy range classification
            4.2.1 Low energy in vivo monitoring (range from 10 keV
                   to 200 keV)
            4.2.2 High energy in vivo monitoring (range from 100 keV
                   to 3 MeV)
       4.3 Specificity of the measurement
            4.3.1 Type 1 - Nuclide specific, spatially specific
                   with very low background
            4.3.2 Type 2 - Nuclide specific, spatially specific with
                   low background
            4.3.3 Type 3 - Nuclide specific
            4.3.4 Type 4 - Non-nuclide and non-spatial specific
    5 General
       5.1 General description of the instrument
            5.1.1 General
            5.1.2 Detection assembly
            5.1.3 Measurement assembly
            5.1.4 Auxiliary equipment
            5.1.5 Ease of operation
            5.1.6 Ease of decontamination
            5.1.7 Size of subject
       5.2 Measurement method
       5.3 Energy range
       5.4 Background
       5.5 Measurement range
       5.6 Minimum detectable activity
    6 Characteristics of equipment for low-energy emitter measurement
       6.1 Energy range (10 keV to 200 keV)
       6.2 Minimum detectable activity
       6.3 Ranges of measurement of activity
       6.4 Energy resolution
       6.5 Integral non-linearity
       6.6 Natural background level
       6.7 Reference radiation response
    7 Characteristics of equipment for high-energy emitter
       measurements 100 keV to 3 MeV
       7.1 Minimum detection activity
       7.2 Ranges of measurement
       7.3 Energy resolution
       7.4 Integral non-linearity
       7.5 Natural background level
       7.6 Reference radiation response
       7.7 Maximum measurable activity
       7.8 Warm-up time
       7.9 Measurement time
    8 Performance requirements and test procedures for low-energy
       emitter measurements
       8.1 General test procedures
            8.1.1 Nature of tests
            8.1.2 Tests performed under standard test conditions
            8.1.3 Tests performed with variation of influence
                   quantities
       8.2 Statistical fluctuations
       8.3 Reference phantom and sources
            8.3.1 General
            8.3.2 Primary phantoms
            8.3.3 Secondary phantoms (radioactive sources)
            8.3.4 Background phantoms
       8.4 Radiation characteristics
            8.4.1 Relative intrinsic error
            8.4.2 Linearity (in relation to activity)
            8.4.3 Energy range determination
            8.4.4 Determination of the integral non-linearity
                   (INL) error
            8.4.5 Determination of the efficiency to Americium-241
                   59,54 keV gamma
            8.4.6 Background
            8.4.7 Determination of minimum detectable activity
            8.4.8 Determination of the maximum count rate
            8.4.9 Determination of stability
            8.4.10 Energy resolution measurement
       8.5 Environmental performance characteristics
            8.5.1 General
            8.5.2 Electromagnetic compatibility
            8.5.3 Ambient temperature
            8.5.4 Relative humidity
            8.5.5 Magnetic fields
            8.5.6 Atmospheric pressure
    9 Performance requirements and test procedures for high-energy
       emitter measurements
       9.1 General test procedures
            9.1.1 Nature of tests
            9.1.2 Tests performed under standard test conditions
            9.1.3 Tests performed with variation of influence
                   quantities
       9.2 Statistical fluctuations
       9.3 Reference phantom and sources
            9.3.1 General
            9.3.2 Primary phantoms
            9.3.3 Secondary phantoms (radioactive sources)
            9.3.4 Background phantoms
       9.4 Radiation characteristics
            9.4.1 Relative intrinsic error
            9.4.2 Linearity
            9.4.3 Response to other radio nuclides
            9.4.4 Energy range determination
            9.4.5 Determination of the integral non-linearity (INL)
                   error
            9.4.6 Determination of the efficiency to Caesium-137
                   661,7 keV gamma
            9.4.7 Determination of the efficiency to Iodine-131
            9.4.8 Cobalt-60 efficiency determination
            9.4.9 Background
            9.4.10 Determination of minimum detection limit
            9.4.11 Determination of the maximum count rate
            9.4.12 Determination of stability
            9.4.13 Energy resolution measurement
       9.5 Environmental performance characteristics
            9.5.1 General
            9.5.2 Electromagnetic compatibility
            9.5.3 Ambient temperature
            9.5.4 Relative humidity
            9.5.5 Magnetic fields
            9.5.6 Atmospheric pressure
    10 Documentation
       10.1 Type test report
       10.2 Certificate
       10.3 Operation and maintenance manual
    Annex A (informative) A guide to the number of independent
                          instrument readings required to establish
                          a true difference in indication (relevant
                          for normal distribution)
    Annex B (normative) Additional requirements and test
                          procedures for transportable and portable
                          assemblies
    Bibliography

    Abstract - (Show below) - (Hide below)

    Specifies the classification, general design requirements, performance characteristics and test procedures for in vivo counting systems for detecting trace amounts of radionuclides in the bodies of persons working in nuclear power plants, laboratories and facilities handling radionuclides, and inhabitants living on territory which may be contaminated. The purpose is to determine the dose equivalent to organs and the effective dose of internal radiation for the whole body.

    General Product Information - (Show below) - (Hide below)

    Committee TC 45/SC 45B
    Development Note Stability Date: 2017. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    IEC 60050-394:2007 International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
    ISO 11929-4:2001 Determination of the detection limit and decision threshold for ionizing radiation measurements Part 4: Fundamentals and application to measurements by use of linear-scale analogue ratemeters, without the influence of sample treatment
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 60721-3-7:1995+AMD1:1996 CSV Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use
    IEC 60721-3-5:1997 Classification of environmental conditions - Part 3: Classificationof groups of environmental parameters and their severities -Section 5: Ground vehicle installations
    IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-12 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-12: TESTING AND MEASUREMENT TECHNIQUES - RING WAVE IMMUNITY TEST
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    ISO 11929-1:2000 Determination of the detection limit and decision threshold for ionizing radiation measurements Part 1: Fundamentals and application to counting measurements without the influence of sample treatment
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    IEC 60050-393:2003 International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts