• Shopping Cart
    There are no items in your cart

IEC 61663-2:2001

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Lightning protection - Telecommunication lines - Part 2: Lines using metallic conductors

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

31-12-2021

Language(s)

English - French, Spanish, Castilian

Published date

07-03-2001

€311.90
Excluding VAT

FOREWORD
INTRODUCTION
Clause
1 Scope and object
2 Normative references
3 Definitions
4 Reference configuration
5 Environmental factor Ke, installation factor Ki,
  shielding factor Ks and conventional transition
  point length LcT
  5.1 Environmental factor Ke
  5.2 Installation factor Ki
  5.3 Shielding factor Ks
  5.4 Conventional transition point length LcT
6 Protection need
  6.1 General
  6.2 Protection need against indirect lightning to
      the telecommunication line
  6.3 Protection need against direct lightning to the
      structure that the telecommunication line enters
  6.4 Protection need against direct lightning to the
      telecommunication line
7 Protection measures
  7.1 General
  7.2 Protective measures against indirect lightning
      to the telecommunication line
  7.3 Protective measures against direct lightning to
      the structure that the telecommunication line enters
  7.4 Protective measures against direct lightning to
      the telecommunication lines
Annex A (normative) Procedure for evaluating the
        protection needs against lightning of
        telecommunication or signal lines using
        metallic conductors
Annex B (normative) Resistance value of the cable shield
        connection to earth along the telecommunication
        line
Annex C (normative) Evaluation of the lightning current
        I striking the structure which causes damage
        to the telecommunication line entering the structure
Annex D (informative) Overvoltages, overcurrents and
        frequency of damage Fp on a telecommunication line
Annex E (informative) Relative amount of expected
        losses per damage
Annex F (informative) Application of protection need
        requirements: examples
Annex G (informative) Environmental factor Ke
Annex H (informative) Risk of damage Rp
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Deals with protection against lightning of outdoor telecommunication lines using metallic conductors (for example, access networks, lines between buildings).These lines concern:- telecommunication lines connecting a switch with a network termination (NT1)- telecommunication or signal lines connecting equipment located in different buildings, e.g. ISDN lines or signal lines between computers.The object of this standard is to protect telecommunication lines and connected equipment against the direct and indirect influence of lightning by limiting the risk of damage due to overvoltages and overcurrents, liable to occur in these lines, to values which are lower than or equal to tolerable risk of damage.The type of building can also have an effect on the risk assessment of lightning damage to telecommunication lines, as well as the physical layout of the equipment installation. However, these and other similar aspects are covered by appropriate, specific standards and are beyond the scope of this standard.Fibre optical cable with metallic pairs in the cable core must be protected, following the requirements of this standard, together with those requirements defined in IEC 61663-1.

DevelopmentNote
Also numbered as BS EN 61663-2. (01/2002)
DocumentType
Standard
Pages
103
PublisherName
International Electrotechnical Committee
Status
Withdrawn

Standards Relationship
CEI EN 61663-2 : 2003 Identical
VDE 0845-4-2 : 2002 Identical
DIN EN 61663-2 : 2002 Identical
NF EN 61663-2 : 2001 Identical
EN 61663-2 : 2001 Identical
I.S. EN 61663-2:2001 Identical
NEN EN IEC 61663-2 : 2001 Identical
PN EN 61663-2 : 2002 Identical
UNE-EN 61663-2:2003 Identical

00/246962 DC : DRAFT JAN 2001 IEC 61643-22 ED 1.0 - SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALING NETWORKS - PART 22: SELECTION AND APPLICATION PRINCIPLES
PD IEC/TR 62066:2002 Surge overvoltages and surge protection in low-voltage a.c. power systems. General basic information
IEC TR 62066:2002 Surge overvoltages and surge protection in low-voltage a.c. power systems - General basic information
EN 50289-4-14:2003 Communication cables - Specifications for test methods - Part 4-14: Environmental test methods - Lightning
PD IEC/TR 61400-24:2002 Wind turbine generator systems Lightning protection
PD CLC/TR 50450:2006 Resistibility requirements for equipment having (a) telecommunication port(s)
I.S. CLC/TR 50450:2006 RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S)
CEI EN 50174-3 : 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
12/30260552 DC : 0 BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
BS EN 50289-4-14:2003 Communication cables. Specifications for test methods. Environmental test methods Lightning
CEI EN 50468 : 2010 RESISTIBILITY REQUIREMENTS TO OVERVOLTAGES AND OVERCURRENTS DUE TO LIGHTNING FOR EQUIPMENT HAVING TELECOMMUNICATION PORTS
I.S. CLC TS 61643-22:2006 LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES
I.S. EN 50174-3:2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
CLC/TR 50450:2006 Resistibility requirements for equipment having (a) telecommunication port(s)
CSA C61400-24 : 2007 WIND TURBINE GENERATOR SYSTEMS - PART 24: LIGHTNING PROTECTION
PREN 50174-3 : DRAFT 2012 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
EN 50468:2009 Resistibility requirements to overvoltages and overcurrents due to lightning for equipment having telecommunication ports
02/209118 DC : DRAFT SEP 2002 PREN 50289-4-14 - COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-14: ENVIRONMENTAL TEST METHODS - LIGHTNING
BS EN 50468:2009 Resistibility requirements to overvoltages and overcurrents due to lightning for equipment having telecommunication ports
05/30134962 DC : DRAFT JUN 2005 CENELEC TS 61643-22 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES
IEC TR 61400-24:2002 Wind turbine generator systems - Part 24: Lightning protection
DD CLC/TS 61643-22:2006 Low-voltage surge protective devices Surge protective devices connected to telecommunications and signalling networks. Selection and application principles
I.S. EN 50468:2009 RESISTIBILITY REQUIREMENTS TO OVERVOLTAGES AND OVERCURRENTS DUE TO LIGHTNING FOR EQUIPMENT HAVING TELECOMMUNICATION PORTS
EN 50174-3:2013/A1:2017 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
DIN 56950:2005-04 ENTERTAINMENT TECHNOLOGY - MACHINERY INSTALLATIONS - SAFETY REQUIREMENTS AND TESTING
CEI CLC/TR 50450 : 2006 RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S)
CEI EN 61663-1 : 2000 LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1: FIBRE OPTIC INSTALLATIONS
BS EN 50174-3 : 2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS

IEC 61024-1-1:1993 Protection of structures against lightning - Part 1: General principles - Section 1: Guide A: Selection of protection levels for lightning protection systems
IEC 61663-1:1999 Lightning protection - Telecommunication lines - Part 1: Fibre optic installations
IEC 61312-1:1995 Protection against lightning electromagnetic impulse - Part 1: General principles
IEC 60364-4-443:1995+AMD1:1998 CSV Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 443: Protection against overvoltages of atmospheric origin or due to switching
EN 50310:2016 Telecommunications bonding networks for buildings and other structures

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.