FOREWORD
INTRODUCTION
Clause
1 Scope and object
2 Normative references
3 Definitions
4 Reference configuration
5 Environmental factor Ke, installation factor Ki,
shielding factor Ks and conventional transition
point length LcT
5.1 Environmental factor Ke
5.2 Installation factor Ki
5.3 Shielding factor Ks
5.4 Conventional transition point length LcT
6 Protection need
6.1 General
6.2 Protection need against indirect lightning to
the telecommunication line
6.3 Protection need against direct lightning to the
structure that the telecommunication line enters
6.4 Protection need against direct lightning to the
telecommunication line
7 Protection measures
7.1 General
7.2 Protective measures against indirect lightning
to the telecommunication line
7.3 Protective measures against direct lightning to
the structure that the telecommunication line enters
7.4 Protective measures against direct lightning to
the telecommunication lines
Annex A (normative) Procedure for evaluating the
protection needs against lightning of
telecommunication or signal lines using
metallic conductors
Annex B (normative) Resistance value of the cable shield
connection to earth along the telecommunication
line
Annex C (normative) Evaluation of the lightning current
I striking the structure which causes damage
to the telecommunication line entering the structure
Annex D (informative) Overvoltages, overcurrents and
frequency of damage Fp on a telecommunication line
Annex E (informative) Relative amount of expected
losses per damage
Annex F (informative) Application of protection need
requirements: examples
Annex G (informative) Environmental factor Ke
Annex H (informative) Risk of damage Rp
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Deals with protection against lightning of outdoor telecommunication lines using metallic conductors (for example, access networks, lines between buildings).These lines concern:- telecommunication lines connecting a switch with a network termination (NT1)- telecommunication or signal lines connecting equipment located in different buildings, e.g. ISDN lines or signal lines between computers.The object of this standard is to protect telecommunication lines and connected equipment against the direct and indirect influence of lightning by limiting the risk of damage due to overvoltages and overcurrents, liable to occur in these lines, to values which are lower than or equal to tolerable risk of damage.The type of building can also have an effect on the risk assessment of lightning damage to telecommunication lines, as well as the physical layout of the equipment installation. However, these and other similar aspects are covered by appropriate, specific standards and are beyond the scope of this standard.Fibre optical cable with metallic pairs in the cable core must be protected, following the requirements of this standard, together with those requirements defined in IEC 61663-1.
DevelopmentNote |
Also numbered as BS EN 61663-2. (01/2002)
|
DocumentType |
Standard
|
Pages |
103
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
CEI EN 61663-2 : 2003 | Identical |
VDE 0845-4-2 : 2002 | Identical |
DIN EN 61663-2 : 2002 | Identical |
NF EN 61663-2 : 2001 | Identical |
EN 61663-2 : 2001 | Identical |
I.S. EN 61663-2:2001 | Identical |
NEN EN IEC 61663-2 : 2001 | Identical |
PN EN 61663-2 : 2002 | Identical |
UNE-EN 61663-2:2003 | Identical |
00/246962 DC : DRAFT JAN 2001 | IEC 61643-22 ED 1.0 - SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALING NETWORKS - PART 22: SELECTION AND APPLICATION PRINCIPLES |
PD IEC/TR 62066:2002 | Surge overvoltages and surge protection in low-voltage a.c. power systems. General basic information |
IEC TR 62066:2002 | Surge overvoltages and surge protection in low-voltage a.c. power systems - General basic information |
EN 50289-4-14:2003 | Communication cables - Specifications for test methods - Part 4-14: Environmental test methods - Lightning |
PD IEC/TR 61400-24:2002 | Wind turbine generator systems Lightning protection |
PD CLC/TR 50450:2006 | Resistibility requirements for equipment having (a) telecommunication port(s) |
I.S. CLC/TR 50450:2006 | RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S) |
CEI EN 50174-3 : 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
12/30260552 DC : 0 | BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
BS EN 50289-4-14:2003 | Communication cables. Specifications for test methods. Environmental test methods Lightning |
CEI EN 50468 : 2010 | RESISTIBILITY REQUIREMENTS TO OVERVOLTAGES AND OVERCURRENTS DUE TO LIGHTNING FOR EQUIPMENT HAVING TELECOMMUNICATION PORTS |
I.S. CLC TS 61643-22:2006 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES |
I.S. EN 50174-3:2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
CLC/TR 50450:2006 | Resistibility requirements for equipment having (a) telecommunication port(s) |
CSA C61400-24 : 2007 | WIND TURBINE GENERATOR SYSTEMS - PART 24: LIGHTNING PROTECTION |
PREN 50174-3 : DRAFT 2012 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 50468:2009 | Resistibility requirements to overvoltages and overcurrents due to lightning for equipment having telecommunication ports |
02/209118 DC : DRAFT SEP 2002 | PREN 50289-4-14 - COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-14: ENVIRONMENTAL TEST METHODS - LIGHTNING |
BS EN 50468:2009 | Resistibility requirements to overvoltages and overcurrents due to lightning for equipment having telecommunication ports |
05/30134962 DC : DRAFT JUN 2005 | CENELEC TS 61643-22 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES |
IEC TR 61400-24:2002 | Wind turbine generator systems - Part 24: Lightning protection |
DD CLC/TS 61643-22:2006 | Low-voltage surge protective devices Surge protective devices connected to telecommunications and signalling networks. Selection and application principles |
I.S. EN 50468:2009 | RESISTIBILITY REQUIREMENTS TO OVERVOLTAGES AND OVERCURRENTS DUE TO LIGHTNING FOR EQUIPMENT HAVING TELECOMMUNICATION PORTS |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
DIN 56950:2005-04 | ENTERTAINMENT TECHNOLOGY - MACHINERY INSTALLATIONS - SAFETY REQUIREMENTS AND TESTING |
CEI CLC/TR 50450 : 2006 | RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S) |
CEI EN 61663-1 : 2000 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1: FIBRE OPTIC INSTALLATIONS |
BS EN 50174-3 : 2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
IEC 61024-1-1:1993 | Protection of structures against lightning - Part 1: General principles - Section 1: Guide A: Selection of protection levels for lightning protection systems |
IEC 61663-1:1999 | Lightning protection - Telecommunication lines - Part 1: Fibre optic installations |
IEC 61312-1:1995 | Protection against lightning electromagnetic impulse - Part 1: General principles |
IEC 60364-4-443:1995+AMD1:1998 CSV | Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 443: Protection against overvoltages of atmospheric origin or due to switching |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |