IEC 61689:2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

31-12-2021

Language(s)

English

Published date

09-08-2007

Is applicable to ultrasonic equipment designed for physiotherapy consisting of an ultrasonic transducer generating continuous or quasi-continuous wave ultrasonic energy in the frequency range 0,5 MHz to 5 MHz.This standard only relates to ultrasonic physiotherapy equipment employing a single plane unfocused circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head.This standard specifies:- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods;- characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods;- guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment;- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods;- acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods.Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not covered by the scope of this standard.This second edition cancels and replaces the first edition published in 1996 and constitutes a technical revision.This second edition is a result of maintenance on this standard and the referenced standards IEC 61161 (2006) and IEC 62127-1. A relatively large technical change is the determination of the effective radiating area. This is now no longer based on the measurement of four areas but only on one. This change was needed to improve the accuracy of the determination of this parameter for small transducers. Be aware that this change may alter the value obtained for this and related parameters.

Committee
TC 87
DocumentType
Standard
Pages
61
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
UNE-EN 61689:2007 Identical

View more information
€353.06
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.