IEC 61753-111-8:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fibre optic interconnecting devices and passive components performance standard - Part 111-8: Sealed closures for category G - Ground
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English - French
10-11-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General requirements
4.1 Storage, transportation and packaging
4.2 Marking and identification
4.3 Materials
4.4 Closure overpressure safety
4.5 Test report
5 Test
5.1 General
5.2 Test specimen preparation
5.3 Test and measurement methods
5.4 Installation or intervention
5.5 Pass/fail criteria
6 Performance requirements
6.1 Sample size
6.2 Sealing, optical and appearance performance criteria
6.3 Mechanical sealing performance requirements
6.4 Environmental sealing performance requirements
6.5 Mechanical optical performance requirements
6.6 Environmental optical performance requirements
Annex A (normative) - Sample definition
Annex B (normative) - Sample size
Annex C (normative) - Intervention and reconfiguration/resplicing
Bibliography
IEC 61753-111-8:2009 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category G - ground, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.
Committee |
TC 86/SC 86B
|
DevelopmentNote |
Stability Date: 2020. (09/2017)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
OVE/ONORM EN 61753-111-8 : 2010 | Identical |
NF EN 61753-111-8 : 2010 | Identical |
NBN EN 61753-111-8 : 2010 | Identical |
NEN EN IEC 61753-111-8 : 2010 | Identical |
I.S. EN 61753-111-8:2010 | Identical |
PN EN 61753-111-8 : 2010 | Identical |
UNE-EN 61753-111-8:2010 | Identical |
BS EN 61753-111-8:2010 | Identical |
CEI EN 61753-111-8 : 2011 | Identical |
EN 61753-111-8:2010 | Identical |
DIN EN 61753-111-8:2010-10 | Identical |
PNE-FprEN 61753-111-8 | Identical |
IEC GUIDE 109:2012 | Environmental aspects - Inclusion in electrotechnical product standards |
IEC 60794-3:2014 | Optical fibre cables - Part 3: Outdoor cables - Sectional specification |
IEC 61300-3-28:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 61300-2-37:2016 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures |
IEC 60793-2:2015 | Optical fibres - Part 2: Product specifications - General |
IEC 61300-3-3:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss |
IEC 61300-2-1:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) |
IEC 61300-2-12:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact |
IEC 61300-2-11:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-11: Tests - Axial compression |
IEC 61300-2-9:2017 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-9: Tests - Shock |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
IEC 61753-1:2007 | Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards |
IEC 61300-2-5:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion |
IEC 61300-2-26:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist |
IEC 61300-2-38:2006 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-38: Tests - Sealing for pressurized fibre optic closures |
IEC 61300-2-22:2007 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature |
IEC 61300-1:2016 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance |
ISO 4892-3:2016 | Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
IEC 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 62134-1:2009 | Fibre optic interconnecting devices and passive components - Fibre optic closures - Part 1: Generic specification |
IEC 61300-2-34:2009 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures |
IEC 60793-2-50:2015 | Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres |
IEC 61300-2-33:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures |
IEC 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
IEC 61300-2-4:1995 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention |
IEC 61753-111-7:2009 | Fibre optic interconnecting devices and passive components performance standard - Part 111-7: Sealed closures for category A - Aerial |
IEC 61300-3-1:2005 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination |
IEC 60721-3-1:1997 | Classification of environmental conditions - Part 3 Classification of groups of environmental parameters and their severities - Section 1: Storage |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.