IEC 61779-6:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by

Electrical apparatus for the detection and measurement of flammable gases - Part 6: Guide for the selection, installation, use and maintenance of apparatus for the detection and measurement of flammable gases
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
16-08-2007
English
30-06-1999
FOREWORD
INTRODUCTION
1 General
1.1 Scope
1.2 Normative references
2 Definitions
3 Measuring principles
3.1 Catalytic sensor
3.2 Thermal conductivity sensor
3.3 Electromagnetic radiation absorption sensor -
usually infrared
3.4 Semi-conductor sensor
3.5 Electrochemical sensors
3.6 Flame ionization detectors (FID)
4 Selection of apparatus
4.1 General
4.2 Selection criteria
4.3 Miscellaneous factors affecting selection of
apparatus
5 Behaviour of gas releases
5.1 Nature of a release
5.2 Outdoor sites and open structures
5.3 Buildings and enclosures
5.4 Environmental considerations
6 Installation of fixed gas detection apparatus
6.1 Basic considerations for the installation of fixed
systems
6.2 Location of sensors
6.3 Installation of sensors
6.4 Timing of installation during construction operations
6.5 Safety in fixed systems
6.6 Environmental conditions
6.7 Sample lines
6.8 Access for calibration and maintenance
6.9 Commissioning
6.10 Operating instructions, plans and records
7 Use of portable and transportable flammable gas detection
apparatus
7.1 General
7.2 Initial and periodic check procedures for portable
and transportable instrumentation
7.3 Guidance on the use of portable and transportable
apparatus
8 Special precautions for fixed and portable apparatus
9 Maintenance, routine procedures and general
administrative control
9.1 General
9.2 Operational checks
9.3 Maintenance
9.4 Sensors
9.5 Flow systems
9.6 Readout devices
9.7 Alarms
9.8 Workshop calibration test
9.9 Routine tests and re-calibration procedures
9.10 General administrative control
10 Training
Annex A (informative) Flammability limits (LFL and UFL) of
certain flammable gases and vapours
Annex B (informative) Environmental and application
check-list for flammable gas detectors (typical)
Annex C (informative) Instrument maintenance record for
flammable gas detectors (typical)
Annex D (informative) Minimum environmental demands for
IEC 61779-4 (group II 100 % LFL) and IEC 61779-5
(group II 100 % (v/v) gas)
Gives guidance on the selection, installation, use and maintenance of electrically operated group II apparatus for the detection and measurement of flammable gases complying with the requirements of IEC 61779-1 to IEC 61779-5. For the purpose of this standard, flammable gases shall include flammable vapours. This standard applies only to group II apparatus intended for use in industrial and commercial safety applications, involving areas classified in accordance with IEC 60079-10.
DevelopmentNote |
A BILINGUAL VERSION OF THIS STANDARD MAY BE ISSUED AT A LATER DATE (08/2000)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN EN 50073 : 1999 | Identical |
BS ISO 16110-1:2007 | Hydrogen generators using fuel processing technologies Safety |
06/30157092 DC : 0 | ISO/DIS 21789 - GAS TURBINE APPLICATIONS - SAFETY |
NF ISO 16110-1 : 2009 | HYDROGEN GENERATORS USING FUEL PROCESSING TECHNOLOGIES - PART 1: SAFETY |
05/30060689 DC : DRAFT JUN 2005 | IEC 62282-3-1 - FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER PLANTS - SAFETY |
IEC 62282-3-1:2007 | Fuel cell technologies - Part 3-1: Stationary fuel cell power systems - Safety |
EN 62282-3-1:2007 | Fuel cell technologies - Part 3-1: Stationary fuel cell power systems - Safety |
EN 62282-3-3:2008 | Fuel cell technologies - Part 3-3: Stationary fuel cell power systems - Installation |
ISA TR12.13.03 : 2009 | GUIDE FOR COMBUSTIBLE GAS DETECTION AS A METHOD OF PROTECTION |
I.S. EN 62282-3-1:2007 | FUEL CELL TECHNOLOGIES - PART 3-1: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY |
NF EN 62282-3-3 : 2008 | FUEL CELL TECHNOLOGIES - PART 3-3: STATIONARY FUEL CELL POWER SYSTEMS - INSTALLATION |
ISO 16110-1:2007 | Hydrogen generators using fuel processing technologies Part 1: Safety |
UNE-EN 62282-3-1:2011 | Fuel cell technologies - Part 3-1: Stationary fuel cell power systems - Safety |
BS EN 62282-3-1:2007 | Fuel cell technologies Stationary fuel cell power systems. Safety |
I.S. EN 62282-3-3:2008 | FUEL CELL TECHNOLOGIES - PART 3-3: STATIONARY FUEL CELL POWER SYSTEMS - INSTALLATION |
IEC 62282-3-3:2007 | Fuel cell technologies - Part 3-3: Stationary fuel cell power systems - Installation |
UNE-ISO 16110-1:2015 | Hydrogen generators using fuel processing technologies -- Part 1: Safety |
04/30089617 DC : DRAFT MARCH 2004 | |
BS EN 62282-3-3:2008 | Fuel cell technologies Stationary fuel cell power systems. Installation |
API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
API 500 : 2012 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 60079-10:2002 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
IEC TR 60079-20:1996 | Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 61779-2:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5 % methane in air |
IEC TR 60079-16:1990 | Electrical apparatus for explosive gas atmospheres. Part 16: Artificial ventilation for the protection of analyser(s) houses |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-3:1990 | Electrical apparatus for explosive gas atmospheres - Part 3: Spark-test apparatus for intrinsically-safe circuits |
IEC 61779-4:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 4: Performance requirements for group II apparatus indicating up to 100% lower explosive limit |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 61779-3:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100 % methane in air |
IEC 61779-5:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100 % gas |
IEC TR 60079-12:1978 | Electrical apparatus for explosive gas atmospheres - Part 12:Classification of mixtures of gases of vapours with air accordingto their maximum experimental safe gaps and minimum ignitingcurrents |
IEC 61779-1:1998 | Electrical apparatus for the detection and measurement of flammable gases - Part 1: General requirements and test methods |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
IEC 60079-4A:1970 | Electrical apparatus for explosive gas atmospheres - Part 4: Method of test for ignition temperature - First supplement. *Note.-This supplement applies also to the second edition of 1975 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.