IEC 61828:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English, English - French, Spanish, Castilian
29-05-2001
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 General
3.1 Focusing transducers
3.2 System and measurement requirements
3.3 General focused field descriptions
4 Focusing definitions
4.1 Background information
4.2 Definitions
5 List of symbols
6 Measurement procedures
6.1 General
6.2 Finding the beam axis
6.3 Determining if transducer is focusing
6.4 Measuring other focal parameters of a focusing transducer
Annex A (informative) Background for the transmission/Characteristics
of focusing transducers
Annex B (informative) Methods for determining the beam axis for
well-behaved beams
Annex C (informative) Methods for determining the beam axis for
beams that are not well-behaved
Bibliography
Figures
Tables
This International Standard- provides definitions for the transmitted field characteristics of focusing transducers for applications in medical ultrasound;- relates these definitions to theoretical descriptions, design, and measurement of the transmitted fields of focusing transducers;- gives measurement methods for obtaining defined characteristics of focusing transducers;- specifies beam axis alignment methods appropriate for focusing transducers.This International Standard relates to focusing ultrasonic transducers operating in the frequency range appropriate to medical ultrasound (0,5 MHz to 40 MHz) for both therapeutic and diagnostic applications. It shows how the characteristics of the transmitted field of transducers may be described from the point of view of design, as well as measured by someone with no prior knowledge of the construction details of a particular device. The radiated ultrasound field for a specified excitation is measured by a hydrophone in either a standard test medium (for example, water) or in a given medium. The standard applies only to media where the field behaviour is essentially like that in a fluid (i.e. where the influence of shear waves and elastic anisotropy is small), including soft tissues and tissue-mimicking gels. Any aspects of the field that affect their theoretical description or are important in design are also included. These definitions would have use in scientific communications, system design and description of the performance and safety of systems using these devices.
Committee |
TC 87
|
DevelopmentNote |
Also numbered as BS EN 61828 (03/2002) A bilingual edition has been published. (07/2006) Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
OVE/ONORM EN 61828 : 2003 | Identical |
GOST R IEC 61828 : 2012 | Identical |
NEN EN IEC 61828 : 2001 | Identical |
I.S. EN 61828:2001 | Identical |
PN EN 61828 : 2002 | Identical |
SN EN 61828 : 2001 | Identical |
CEI EN 61828 : 2003 | Identical |
EN 61828:2001 | Identical |
DIN EN 61828:2016-02 (Draft) | Identical |
UNE-EN 61828:2003 | Identical |
I.S. EN 61391-1:2006 | Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of system point-spread function response |
PD IEC/TS 62556:2014 | Ultrasonics. Field characterization. Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems |
CLC/TS 61949:2008 | Ultrasonics - Field characterization - In situ exposure estimation in finite-amplitude ultrasonic beams |
UNE-IEC 60050-802:2011 | International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics |
S.R. CLC/TS 61949:2008 | ULTRASONICS - FIELD CHARACTERIZATION - IN SITU EXPOSURE ESTIMATION IN FINITE-AMPLITUDE ULTRASONIC BEAMS |
BS EN 62127-1 : 2007 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ |
I.S. EN 60601-2-62:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-62: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH INTENSITY THERAPEUTIC ULTRASOUND (HITU) EQUIPMENT |
BS EN 62127-2 : 2007 | ULTRASONICS - HYDROPHONES - PART 2: CALIBRATION FOR ULTRASONIC FIELDS UP TO 40 MHZ |
NF EN 62127-1 : 2008 AMD 1 2013 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ |
EN 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
EN 62092:2001 | Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz |
BS EN 61391-1 : 2006 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE |
08/30177589 DC : DRAFT FEB 2008 | BS EN 62359 - ULTRASONIC - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
CEI EN 61689 : 2013 | ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ |
NF EN 62127-2 : 2008 AMD 2 2017 | ULTRASONICS - HYDROPHONES - PART 2: CALIBRATION FOR ULTRASONIC FIELDS UP TO 40 MHZ |
IEC TS 62556:2014 | Ultrasonics - Field characterization - Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems |
I.S. EN 62359:2011 | ULTRASONICS - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
IEC 62127-2:2007+AMD1:2013+AMD2:2017 CSV | Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz |
BS EN 60601-2-62:2015 | Medical electrical equipment Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
PD IEC/TS 62903:2018 | Ultrasonics. Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method |
BS EN 62359 : 2011 | ULTRASONICS - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
IEC TR 62649:2010 | Requirements for measurement standards for high intensity therapeutic ultrasound (HITU) devices |
CSA C22.2 No. 60601-2-62 : 2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-62: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH INTENSITY THERAPEUTIC ULTRASOUND (HITU) EQUIPMENT |
IEC TS 61949:2007 | Ultrasonics - Field characterization - In situ exposure estimation in finite-amplitude ultrasonic beams |
IEC TS 62903:2018 | Ultrasonics - Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method |
BS EN 61689:2013 | Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
CEI EN 61391-1 : 2007 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE |
12/30191872 DC : 0 | BS EN 60601-2-62 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-62: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH INTENSITY THERAPEUTIC ULTRASOUND (HITU) SYSTEM |
CEI CLC/TS 61949 : 2011 | ULTRASONICS - FIELD CHARACTERIZATION - IN SITU EXPOSURE ESTIMATION IN FINITE-AMPLITUDE ULTRASONIC BEAMS |
CEI EN 62359 : 2012 | ULTRASONICS - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
I.S. EN 62127-2:2007 | ULTRASONICS - HYDROPHONES - PART 2: CALIBRATION FOR ULTRASONIC FIELDS UP TO 40 MHZ |
IEC 60050-802:2011 | International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics |
IEC 61391-1:2006+AMD1:2017 CSV | Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response |
IEC 62127-1:2007+AMD1:2013 CSV | Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz |
IEC 60601-2-62:2013 | Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
17/30355518 DC : 0 | BS EN 63045 - ULTRASONICS - NON-FOCUSING AND WEAKLY FOCUSING PRESSURE PULSE SOURCES - CHARACTERISTICS OF FIELDS |
11/30228850 DC : 0 | BS EN 62127-2 AMD 1 - ULTRASONICS - HYDROPHONES - PART 2: CALIBRATION FOR ULTRASONIC FIELDS UP TO 40 MHZ |
I.S. EN 61689:2013 | ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ (IEC 61689:2013 (EQV)) |
BS EN 62092:2002 | Ultrasonics. Hydrophones. Characteristics and calibration in the frequency range from 15 MHz to 40 MHz |
I.S. EN 62127-1:2007 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007 (EQV)) |
EN 62127-2:2007/A2:2017 | ULTRASONICS - HYDROPHONES - PART 2: CALIBRATION FOR ULTRASONIC FIELDS UP TO 40 MHZ |
EN 62127-1:2007/A1:2013 | ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007/A1:2013) |
IEC 62359:2010+AMD1:2017 CSV | Ultrasonics - Field characterization - Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields |
IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
IEC 62092:2001 | Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz |
EN 61391-1:2006/A1:2017 | ULTRASONICS - PULSE-ECHO SCANNERS - PART 1: TECHNIQUES FOR CALIBRATING SPATIAL MEASUREMENT SYSTEMS AND MEASUREMENT OF SYSTEM POINT-SPREAD FUNCTION RESPONSE (IEC 61391-1:2006/A1:2017) |
EN 62359:2011/A1:2018 | ULTRASONICS - FIELD CHARACTERIZATION - TEST METHODS FOR THE DETERMINATION OF THERMAL AND MECHANICAL INDICES RELATED TO MEDICAL DIAGNOSTIC ULTRASONIC FIELDS |
EN 60601-2-62:2015 | Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
IEC 61161:2013 | Ultrasonics - Power measurement - Radiation force balances and performance requirements |
IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
IEC TR 60854:1986 | Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment |
IEC 60469-1:1987 | Pulse techniques and apparatus. Part 1: Pulse terms and definitions |
IEC 60050-801:1994 | International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics |
IEC 62092:2001 | Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz |
IEC 61157:2007+AMD1:2013 CSV | Standard means for the reporting of the acoustic output of medicaldiagnostic ultrasonic equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.