IEC 61967-2:2005

Current

Current

The latest, up-to-date edition.

Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 2: Measurement of radiated emissions - TEM cell and wideband TEM cell method

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

29-09-2005

€164.53
Excluding VAT
Summarise this standard

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test conditions
   5.1 General
   5.2 Supply voltage
   5.3 Frequency range
6 Test equipment
   6.1 General
   6.2 Shielding
   6.3 RF measuring instrument
   6.4 Preamplifier
   6.5 TEM cell
   6.6 Wideband TEM/GTEM cell
   6.7 50-Ohm termination
   6.8 System gain
7 Test set-up
   7.1 General
   7.2 Test configuration
   7.3 Test PCB
8 Test procedure
   8.1 General
   8.2 Ambient measurement
   8.3 DUT operational check
   8.4 DUT emissions measurement
9 Test report
   9.1 General
   9.2 Measurement conditions
10 IC emissions reference levels
Annex A (informative) Example calibration & set-up
                      verification sheet
Annex B (informative) TEM cell and wideband TEM cell
                      descriptions
   B.1 TEM cell
   B.2 Wideband GTEM cell
Annex C (informative) Calculation of dipole moment from
                      measured data
   C.1 General
   C.2 Dipole moment calculation
Annex D (informative) Specification of emissions data
   D.1 General
   D.2 Specification of emission levels
   D.3 Presentation of results
   D.4 Examples
Bibliography

This test procedure defines a method for measuring the electromagnetic radiation from an integrated circuit (IC). The IC being evaluated is mounted on an IC test printed circuit board (PCB) that is clamped to a mating port (referred to as a wall port) cut in the top or bottom of a transverse electromagnetic (TEM) or wideband gigahertz TEM (GTEM) cell. The test board is not inside the cell, as in the conventional usage, but becomes a part of the cell wall. This method is applicable to any TEM or GTEM cell modified to incorporate the wall port; however, the measured radio frequency (RF) voltage will be affected by many factors. The primary factor affecting the measured RF voltage is the septum to IC test board (cell wall) spacing. This procedure was developed using a 1 GHz TEM cell with a septum to floor spacing of 45 mm and a GTEM cell with average septum to floor spacing of 45 mm over the port area. Other cells may not produce identical spectral output but may be used for comparative measurements, subject to their frequency and sensitivity limitations. A conversion factor may allow comparisons between data measured on TEM or GTEM cells with different septum to floor spacing. The IC test board controls the geometry and orientation of the operating IC relative to the cell and eliminates any connecting leads within the cell (these are on the backside of the board, which is outside the cell). For the TEM cell, one of the 50 ports is terminated with a 50 load. The other 50 port for a TEM cell, or the single 50 port for a GTEM cell, is connected to the input of a spectrum analyser or receiver that measures the RF emissions emanating from the integrated circuit and impressed onto the septum of the cell.

Committee
TC 47/SC 47A
DevelopmentNote
To be read in conjunction with IEC 61967-1. (10/2005) Stability Date: 2017. (10/2012)
DocumentType
Standard
Pages
43
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
EN 61967-2:2005 Identical
DIN EN 61967-2:2006-03 Identical
NEN EN IEC 61967-2 : 2005 Identical
I.S. EN 61967-2:2005 Identical
PN EN 61967-2 : 2006 Identical
BS EN 61967-2:2005 Identical
CEI EN 61967-2 : 2006 Identical
NF EN 61967-2 : 2006 Identical
UNE-EN 61967-2:2005 Identical
SAC GB/T 44937.2:2025 Identical

€164.53
Excluding VAT