IEC 62153-4-4:2015
Current
The latest, up-to-date edition.
Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
29-04-2015
FOREWORD
1 Scope
2 Normative references
3 Symbols and theoretical background
4 Principles of the measuring method
5 Measurement
6 Requirement
Annex A (normative) - Determination of the impedance of
the inner circuit
Annex B (informative) - Example of a self-made impedance
matching adapter
Annex C (informative) - Reflection loss of a junction
Bibliography
IEC 62153-4-4:2015(E) describes a test method to determine the screening attenuation as of metallic communication cable screens. Due to the concentric outer tube, measurements are independent of irregularities on the circumference and outer electromagnetic field. A wide dynamic frequency range can be applied to test even super-screened cables with normal instrumentation from low frequencies up to the limit of defined transversal waves in the outer circuit at approximately 4 GHz. This second edition cancels and replaces the first edition, published in 2006 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Impedance matching adapters are no longer required when measuring devices have a characteristic impedance different from the characteristic impedance of the test equipment;
- The reflection loss due to a mismatch is taken into account by a (calculated) correction factor.
Committee |
TC 46
|
DevelopmentNote |
Stability Date: 2020. (05/2015)
|
DocumentType |
Standard
|
Pages |
19
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN IEC 62153-4-4 : 2015 | Identical |
15/30332390 DC : 0 | BS EN 50117-10-1 - COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
15/30332399 DC : 0 | BS EN 50117-11-2 - COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ |
IEC 62153-4-16:2016 | Metallic communication cable test methods - Part 4-16: Electromagnetic compatibility (EMC) - Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up |
IEC 62153-4-9:2018 RLV | Metallic communication cable test methods - Part 4 - 9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method |
IEC 62153-4-10:2015 | Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method |
BS IEC 61196-9:2014 | Coaxial communication cables Sectional specification for RF flexible cables |
IEC 61196-6-1:2009 | Coaxial communication cables - Part 6-1: Blank detail specification for CATV drop cables |
15/30332396 DC : 0 | BS EN 50117-11-1 - COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
15/30334758 DC : 0 | BS IEC 62153-4-16 ED 1.0 - I METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-16: EXTENSION OF THE FREQUENCY RANGE TO HIGHER FREQUENCIES FOR TRANSFER IMPEDANCE AND TO LOWER FREQUENCIES FOR SCREENING ATTENUATION MEASUREMENTS USING THE TRIAXIAL SET-UP |
17/30348794 DC : 0 | BS EN 62153-4-7+A1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE ZT AND SCREENING ATTENUATION AS OR COUPLING ATTENUATION AC OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD |
14/30296057 DC : 0 | BS EN 61156-9 ED.1.0 - MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS - PART 9: CABLES FOR HORIZONTAL FLOOR WIRING WITH TRANSMISSION CHARACTERISTICS UP TO 2 GHZ - SECTIONAL SPECIFICATION |
15/30332369 DC : 0 | BS EN 50117-9-1 - COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
SCTE 177 : 2012 | SPECIFICATION FOR BRAIDED 75 OHMS, MINI-SERIES QUAD SHIELD COAXIAL CABLE FOR CMTS AND SDI CABLES |
IEC 61196-9:2014 | Coaxial communication cables - Part 9: Sectional specification for RF flexible cables |
IEC 61196-7:2011 | Coaxial communication cables - Part 7: Sectional specification for cables for BCT cabling in accordance with ISO/IEC 15018 - Indoor drop cables for systems operating at 5 MHz - 3 000 MHz |
15/30332393 DC : 0 | BS EN 50117-10-2 - COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
PD IEC/TR 62153-4-1:2010 | Metallic communication cable test methods Electromagnetic compatibility (EMC). Introduction to electromagnetic (EMC) screening measurements |
17/30363102 DC : DRAFT SEP 2017 | BS EN 63137-1 - STANDARD TEST RADIO-FREQUENCY CONNECTORS - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND TEST METHODS |
17/30354707 DC : 0 | BS ISO 19642-2 - ROAD VEHICLES - AUTOMOTIVE CABLES - PART 2: TEST METHODS |
15/30332386 DC : 0 | BS EN 50117-9-3 - COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ |
13/30279876 DC : 0 | BS EN 62153-4-15 ED.1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-15: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING TRANSFER IMPEDANCE AND SCREENING ATTENUATION - OR COUPLING ATTENUATION WITH TRIAXIAL CELL |
14/30296061 DC : 0 | BS EN 61156-10 ED.1.0 - MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES FOR DIGITAL COMMUNICATIONS - PART 10: CABLES FOR WORK AREA WIRING WITH TRANSMISSION CHARACTERISTICS UP TO 2 GHZ - SECTIONAL SPECIFICATION |
PREN 50117-11-2 : DRAFT 2015 | COAXIAL CABLES - PART 11-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 2000 MHZ |
IEC 62153-4-15:2015 | Metallic communication cable test methods - Part 4-15: Electromagnetic compatibility (EMC) - Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with triaxial cell |
EN 62153-4-7:2016/AC:2016-05 | METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD (IEC 62153-4-7:2015/COR1:2016) |
PREN 50117-10-1 : DRAFT 2015 | COAXIAL CABLES - PART 10-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
PREN 50117-10-2 : DRAFT 2015 | COAXIAL CABLES - PART 10-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - OUTDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
13/30292984 DC : 0 | BS EN 62153-4-10 ED2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-10: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE SCREENING EFFECTIVENESS OF FEED-THROUGHS AND ELECTROMAGNETIC GASKETS DOUBLE COAXIAL METHOD |
13/30283920 DC : 0 | BS EN 62153-4-7 ED.2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE TRANSFER IMPEDANCE Z[T] AND THE SCREENING ATTENUATION A[S] OR THE COUPLING ATTENUATION A[C] OF RF-CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ; TUBE |
PREN 50117-9-3 : DRAFT 2015 | COAXIAL CABLES - PART 9-3: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 6000 MHZ |
BS IEC 62153-4-10:2015 | Metallic communication cable test methods Electromagnetic compatibility (EMC). Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets. Double coaxial test method |
BS IEC 62153-4-15:2015 | Metallic Communication Cable test methods Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation or coupling attenuation with triaxial cell |
IEC 61196-5:2018 | Coaxial communication cables - Part 5: Sectional specification for CATV trunk and distribution cables |
IEC 62153-4-9:2008 | Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method |
IEC 61196-11:2016 | Coaxial communication cables - Part 11: Sectional specification for semi-rigid cables with polyethylene (PE) dielectric |
IEC TR 62153-4-1:2010 | Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic (EMC) screening measurements |
IEC 61196-8:2012 | Coaxial communication cables - Part 8: Sectional specification for semi-flexible cables with polytetrafluoroethylene (PTFE) dielectric |
BS EN 62153-4-7 : 2016 | METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD |
BS IEC 62153-4-16:2016 | Metallic communication cable test methods Electromagnetic compatibility (EMC). Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up |
PREN 50117-11-1 : DRAFT 2015 | COAXIAL CABLES - PART 11-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOQUE AND DIGITAL SIGNAL TRANSMISSION - DISTRIBUTION AND TRUNK CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
PREN 50117-9-1 : DRAFT 2015 | COAXIAL CABLES - PART 9-1: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 1000 MHZ |
12/30265027 DC : 0 | BS EN 61196-9 ED.1 - COAXIAL COMMUNICATION CABLES - PART 9: SECTIONAL SPECIFICATION FOR FLEXIBLE RF COAXIAL CABLES |
15/30332377 DC : 0 | BS EN 50117-9-2 - COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
IEC 61196-5-1:2012 | Coaxial communication cables - Part 5-1: Blank detail specification for CATV trunk and distribution cables |
PREN 50117-9-2 : DRAFT 2015 | COAXIAL CABLES - PART 9-2: SECTIONAL SPECIFICATION FOR COAXIAL CABLES FOR ANALOGUE AND DIGITAL SIGNAL TRANSMISSION - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ |
SCTE 244 : 2018 | SPECIFICATION FOR BRAIDED 75 OHMS, MICRO-SERIES QUAD SHIELD COAXIAL CABLE FOR CONNECTIVITY AND DENSE CCAP/EDGE QAM APPLICATIONS |
I.S. EN 62153-4-7:2016 | METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD |
IEC TS 62153-4-1:2014 | Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
IEC 62153-4-7:2015 | Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method |
CEI EN 62153-4-16:2022 | Metallic cables and other passive components test methods Part 4-16: Electromagnetic compatibility (EMC) - Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up |
IEC TR 62152:2009 | Transmission properties of cascaded two-ports or quadripols - Background of terms and definitions |
IEC TS 62153-4-1:2014 | Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.