• IEC 62271-104:2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages of 52 kV and above

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  31-12-2021

    Language(s):  English - French, Spanish, Castilian

    Published date:  20-04-2009

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Abstract - (Show below) - (Hide below)

    IEC 62271-104:2009 applies to three-pole alternating current switches for rated voltages 52 kV and above, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment. The main object of this standard is to establish requirements for switches used in transmission and distribution systems. General-purpose switches for this application are designed to comply with the following service applications:
    - carrying rated normal current continuously;
    - carrying short-circuit currents for a specified time;
    - switching of mainly active loads;
    - switching of no-load transformers;
    - switching of the charging current of unloaded cables, overhead lines or busbars;
    - switching of closed-loop circuits;
    - making short-circuit currents.
    A further object of this standard is to establish requirements for limited-purpose and special- purpose switches used in transmission and distribution systems. Limited-purpose switches shall comply with one or more of the service applications indicated above. Special-purpose switches may comply with one or more of the service applications indicated above and, in addition, shall be suitable for one or more of the following applications:
    - switching single capacitor banks;
    - switching back-to-back capacitor banks;
    - switching shunt reactors including secondary or tertiary reactors switched from the primary side of the transformer;
    - applications requiring an increased number of operating cycles;
    - switching under earth fault conditions in non-effectively earthed neutral systems.
    This standard cancels and replaces IEC 60265-2:1988. The major changes with respect to IEC 60265-2 are as follows:
    - alignment with IEC 62271-1 and IEC 62271-100;
    - requirements for capacitive current switching aligned with those in IEC 62271-100: classes C1 and C2 are introduced.

    This publication is to be read in conjunction with IEC 62271-1:2007, IEC 62271-100:2008, IEC 62271-102:2001 and IEC 62271-110:2005.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective