IEC/IEEE 60076-57-129:2017
Current
The latest, up-to-date edition.
Power transformers - Part 57-129: Transformers for HVDC applications
09-11-2017
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Use of normative references
5 General requirements
6 Rating data
7 Losses
8 Test requirements
9 Tests
10 Dielectric tests on transformers
that have been in service
11 Sound levels
12 Bushings
13 Tap-changer
14 High-frequency modelling
15 Tolerances
16 Rating plate
Annex A (informative) - In service overloading
of HVDC converter transformers used
with current commutated valves (either
mercury arc valves or thyristors)
Annex B (informative) - HVDC converter
transformers for use with
voltage source converters
Annex C (informative) - Design review
Annex D (informative) - Transformer
specification content
Annex E (informative) - Audible sound of
converter transformers
Annex F (informative) - Determination of
transformer service load loss
at rated non-sinusoidal converter
current from measurements with
rated transformer current of
fundamental frequency
Bibliography
IEC/IEEE 60076-57-129:2017(E) specifies requirements of liquid-immersed three-phase and single-phase converter transformers for use in high voltage direct current (HVDC) power transmission systems including back-to-back applications. It applies to transformers having two, three or multiple windings.
This document does not apply to:
- converter transformers for industrial applications (see IEC 61378-1 or IEEE C57.18.10);
- converter transformers for traction applications (see IEC 60310).
This publication cancels and replaces the first edition of IEC 61378-2 published in 2001 and IEEE Std C57.129™ published in 2007.
Committee |
TC 14
|
DevelopmentNote |
Supersedes IEC 61378-2 and IEEE C57.129. Jointly published by IEC & IEEE. Stability Date: 2022. (11/2017)
|
DocumentType |
Standard
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEC 60099-9:2014 | Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations |
IEC/IEEE 65700-19-03:2014 | Bushings for DC application |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-18:2012 | Power transformers - Part 18: Measurement of frequency response |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEEE C57.149-2012 | IEEE Guide for the Application and Interpretation of Frequency Response Analysis for Oil-Immersed Transformers |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEEE C57.19.00 : 2004 | GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS |
IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
IEC 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
IEC TS 61973:2012 | High voltage direct current (HVDC) substation audible noise |
IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
IEC TR 60146-1-2:2011 | Semiconductor converters - General requirements and line commutated converters - Part 1-2: Application guide |
ANSI C84.1 : 2016 | ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ) |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
IEC 60076-1:2011 | Power transformers - Part 1: General |
ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
IEC 60099-5:2013 | Surge arresters - Part 5: Selection and application recommendations |
IEEE C57.163-2015 | IEEE Guide for Establishing Power Transformer Capability while under Geomagnetic Disturbances |
IEC 61378-3:2015 | Converter transformers - Part 3: Application guide |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEEE C57.130-2015 | IEEE Guide for the Use of Dissolved Gas Analysis Applied to Factory Temperature Rise Tests for the Evaluation of Mineral Oil-Immersed Transformers and Reactors |
IEEE C57.12.10-2010 REDLINE | IEEE Standard Requirements for Liquid-Immersed Power Transformers |
IEC 60076-10-1:2016 | Power transformers - Part 10-1: Determination of sound levels - Application guide |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
IEC 60214-2:2004 | Tap-changers - Part 2: Application guide |
IEC 60214-1:2014 | Tap-changers - Part 1: Performance requirements and test methods |
IEEE C57.131-2012 | IEEE Standard Requirements for Tap Changers |
IEC 60310:2016 | Railway applications - Traction transformers and inductors on board rolling stock |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.