IEC/IEEE 62271-37-013:2021
Current
The latest, up-to-date edition.
High-voltage switchgear and controlgear - Part 37-013: Alternating current generator circuit-breakers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
19-10-2021
IEC/IEEE 62271-37-013:2021 is applicable to three-phase AC high-voltage generator circuit-breakers, hereafter called generator circuit-breakers, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV.
This document is published as an IEC/IEEE Dual Logo standard.
The IEEE Std C37.013™-1997 (R2008) was revised and converted into the first edition of the IEC/IEEE Dual Logo International Standard IEC/IEEE 62271-37-013 published in 2015.
This second edition cancels and replaces the first edition published in 2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
content has been added to address the requirements of the other components of the generator circuit breaker system;
requirements for the application of generator circuit-breakers in power plants with multiple generators connected to one step-up transformer have been added;
requirements for testing and application of Tee-OFF generator circuit-breakers have been added;
requirements for application of generator circuit-breakers in power plants with doubly-fed induction machines, pumped-storage power plants, and wind farms have been added;
the clause numbering has been aligned with the numbering in IEC 62271-1:2017;
the topic of reference mechanical characteristics has been revised to improve clarity;
the modifying effects of capacitors on the prospective TRVs for out-of-phase and load current switching has been addressed in Annex M and in Annex N with use of the tool named "GenCB TRV calculator". This tool provides the values of KE2, RRRV0, KRRRV-U, KRRRV-I, td0, Ktd-U, Ktd-I, as well as the values of the parameters of the prospective TRV modified by the capacitors of the generator circuit-breaker.
This document contains attached files in the form of Excel spreadsheets ("GenCB TRV calculator"). These files are intended to be used as a complement and do not form an integral part of the document.
The content of the corrigendum 1 (2024-11) has been included in this copy.
Committee |
TC 17/SC 17A
|
DocumentType |
Standard
|
ISBN |
978-2-8322-1030-8
|
Pages |
294
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-IEC/IEEE 62271-37-013:2023 | Identical |
I.S. EN IEC 62271-100:2021+AC:2024-02 | High-voltage switchgear and controlgear - Part 100: Alternatingcurrent circuit-breakers (IEC 62271-100:2021/COR3:2024) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.