• IEC PAS 62282-6-1:2006

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Fuel cell technologies - Part 6-1: Micro fuel cell power systems - Safety

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  03-03-2010

    Language(s): 

    Published date:  23-02-2006

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
      1.1 System boundary
      1.2 Equivalent Level of Safety
    2 Normative references
    3 Terms and definitions
    4 Materials and construction of fuel cartridge, micro fuel
      cell power unit and micro fuel cell power system for
      portable devices
      4.1 General
      4.2 FMEA/hazard analysis
      4.3 Fuel Input
      4.4 General materials
      4.5 Selection of materials
      4.6 Vacant
      4.7 General construction
      4.8 Vacant
      4.9 Piping and fittings
      4.10 Fuel containing parts and piping systems
      4.11 Materials and construction - System
      4.12 Ignition sources
      4.13 Enclosures and acceptance strategies
      4.14 Protection against fire, explosion, corrosivity and
           toxicity hazard
      4.15 Protection against electrical hazards
      4.16 Fuel cell stack
      4.17 Fuel supply construction
      4.18 Protection against mechanical hazards
      4.19 Wiring material, including printed wiring
      4.20 Miscellaneous electrical equipment
      4.21 Construction of electric device components
      4.22 Protection
    5 Abnormal operation requirements and tests
      5.1 Abnormal operations and fault conditions
    6 Instructions and warnings for fuel supply cartridges,
      micro fuel cell power units, and micro fuel cell power systems
      6.1 Minimum markings required on the cartridge
      6.2 Additional information required either on the cartridge
          or on accompanying written information or on the system
          or power unit
    7 Type tests for a fuel cartridge, a micro fuel cell power unit,
      and a micro fuel cell power system
      7.1 Test conditions
      7.2 Leakage measurement of methanol and the measuring procedure
      7.3 Type tests
    Annex A (Normative) formic acid fuel cell systems
          A.1 Scope
          A.2 Normative references
          A.3 Terms and definitions
          A.4 Materials and construction of fuel cartridge, micro
              fuel cell power unit, and micro fuel cell power
              system for portable device
          A.5 Requirements of fuel cartridge, micro fuel cell
              power unit, and micro fuel cell power system
          A.6 Instructions and warnings for fuel supply cartridges,
              micro fuel cell power units, and micro fuel cell
              power systems using formic acid as a fuel
          A.7 Type tests for a fuel cartridge, a micro fuel cell
              power unit, and a micro fuel cell power system
    Annex B (normative) Hydrogen stored in hydrogen absorbing metal
                        alloy
          B.1 Scope
          B.2 Normative references
          B.3 Definitions
          B.4 Materials and construction of fuel cartridge, micro
              fuel cell power unit, and micro fuel cell power
              system for portable devices
          B.5 Abnormal operation requirements and tests
          B.6 Instructions for fuel cartridge, micro fuel cell
              power unit, and micro fuel cell power system
          B.7 Type tests for a fuel cartridge, a micro fuel cell
              power unit, and a micro fuel cell power system
    Annex C (Normative) Micro reformed methanol fuel cells
          C.1 Scope
          C.2 Normative references
          C.3 Terms and definitions
          C.4 Materials and construction of fuel cartridge, micro
              fuel cell power unit and micro fuel cell power system
          C.5 Requirements of fuel cartridge, micro fuel cell
              power unit, and micro fuel cell power system
          C.6 Instructions for fuel cartridge, micro fuel cell
              power unit, and micro fuel cell power system
          C.7 Type tests
    Annex D (Normative) Methanol clathrate compound
          D.1 Scope
          D.2 Normative references
          D.3 Terms and definitions
          D.4 Materials and construction of fuel cartridge, micro
              fuel cell power unit, and micro fuel cell power
              system for portable devices
          D.5 Abnormal operation requirements and tests
          D.6 Instructions and warnings for fuel supply cartridges,
              micro fuel cell power units, and micro fuel cell
              power systems
          D.7 Type tests for a fuel cartridge, a micro fuel cell
              power unit, and a micro fuel cell power system
    Annex E (normative) Borohydride compounds
          E.1 Scope
          E.2 Normative references
          E.3 Terms and definitions
          E.4 Materials and construction of fuel cartridge, micro
              fuel cell power unit, and micro fuel cell power system
              for portable devices
          E.5 Abnormal operation requirements and tests
          E.6 Instructions and warnings for fuel supply cartridges,
              micro fuel cell power units, and micro fuel cell power
              systems
          E.7 Type tests for a fuel cartridge, a micro fuel cell
              power unit, and a micro fuel cell power system
    Annex F (Normative) Butane Supplement
          F.1 Scope
          F.2 Normative references
          F.3 Definitions
          F.4 Materials and construction of fuel cartridge, micro
              fuel cell power unit and micro fuel cell power system
              for portable devices
          F.5 Requirements of fuel cartridge, micro fuel cell power
              unit, and micro fuel cell power system
          F.6 Instructions for fuel cartridge, micro fuel cell power
              unit, and micro fuel cell power system
          F.7 Type tests for a fuel cartridge, a micro fuel cell power
              unit, and a micro fuel cell power system

    Abstract - (Show below) - (Hide below)

    Establishes requirements for all fuel cell power systems, units and cartridges to ensure a reasonable degree of safety for normal use, reasonably foreseeable misuse, and consumer transportation of such items. Covers fuel cell power systems, power units and fuel cartridges that are wearable or easily carried by hand, providing d.c. outputs not exceeding 60 V d.c. and power outputs not exceeding 240 VA.The contents of the corrigendum of April 2007 have been included in this copy.

    General Product Information - (Show below) - (Hide below)

    Document Type Miscellaneous Product
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    07/30122750 DC : 0 BS IEC 62282-6-3 - FUEL CELL TECHNOLOGIES - PART 6-3: MICRO FUEL CELL POWER SYSTEMS - INTERCHANGEABILITY
    13/30271415 DC : 0 BS EN 62282-6-400 ED 1.0 - FUEL CELL TECHNOLOGIES - PART 6-400: MICRO FUEL CELL POWER SYSTEMS - POWER AND DATA INTERCHANGEABILITY
    11/30256742 DC : 0 BS EN 62282-6-300 - FUEL CELL TECHNOLOGIES - PART 6-300: MICRO FUEL CELL POWER SYSTEMS - FUEL CARTRIDGE INTERCHANGEABILITY

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61025:2006 Fault tree analysis (FTA)
    IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
    ISO 15649:2001 Petroleum and natural gas industries — Piping
    IEC 61960:2011 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications
    ISO 188:2011 Rubber, vulcanized or thermoplastic — Accelerated ageing and heat resistance tests
    ASME B31.3:2016 PROCESS PIPING
    IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
    ISO 16017-1:2000 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling
    ISO 9772:2012 Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame
    ISO 175:2010 Plastics Methods of test for the determination of the effects of immersion in liquid chemicals
    IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
    ISO 16000-3:2011 Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method
    IEC 60086-4:2014 Primary batteries - Part 4: Safety of lithium batteries
    IEC 61032:1997 Protection of persons and equipment by enclosures - Probes for verification
    ISO 16000-6:2011 Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
    IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    ISO 1817:2015 Rubber, vulcanized or thermoplastic Determination of the effect of liquids
    IEC 60730-1:2013+AMD1:2015 CSV Automatic electrical controls - Part 1: General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective