IEC PAS 62825:2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Methods of measurement and limits for radiated disturbances from plasma display panel TVs in the frequency range 150 kHz to 30 MHz
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-09-2022
English
10-01-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Limits for electromagnetic disturbances
5 Measurement requirements
6 Measurement arrangement and procedure
7 Verification of the compliance of the equipment
with the requirements of this specification
Bibliography
IEC/PAS 62825:2013(E), which is a Publicly Available Specification, applies to plasma display panel TVs which are intended for use in residential or commercial environments, which have a visible display area with a diagonal dimension of 1 m or greater, and which are within the scope of CISPR 13 or CISPR 32. This specification covers emission requirements related to radiated radio-frequency (RF) disturbances in the frequency range 150 kHz to 30 MHz. It specifies suitable limits and methods of measurement for the assessment of radiated RF disturbances. The requirements specified in this specification are essential EMC requirements which should be met in order to protect radio reception in the frequency range up to 30 MHz at locations where these display devices are operated in the field. While application of this specification is recommended, the comprehensive set of normative EMC emission requirements is found in CISPR 13 or CISPR 32. Use of this specification does not remove the obligation to apply any other CISPR publication. The objectives of this specification are to establish supplementary requirements which provide an adequate level of protection of the radio frequency spectrum, allowing radio reception as intended in the frequency range 150 kHz to 30 MHz, and to specify procedures to ensure the reproducibility of measurement and the repeatability of obtained results.
DevelopmentNote |
Stability date: 2016. (01/2013)
|
DocumentType |
Miscellaneous Product
|
Pages |
12
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
PD IEC/PAS 62825:2013 | Identical |
NEN NPR IEC/PAS 62825 : 2012 | Identical |
I.S. EN 55032:2016 | ELECTROMAGNETIC COMPATIBILITY OF MULTIMEDIA EQUIPMENT - EMISSION REQUIREMENTS |
CISPR 32:2015 RLV | Electromagnetic compatibility of multimedia equipment - Emission requirements |
CISPR 13:2009+AMD1:2015 CSV | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement |
BS EN 55032:2015 | Electromagnetic compatibility of multimedia equipment. Emission Requirements |
CAN/CSA-CISPR 32:17 | Electromagnetic compatibility of multimedia equipment — Emission requirements (Adopted IEC CISPR 32:2015, second edition, 2015-03, with Canadian deviations) | Compatibilité électromagnétique des équipements multimédia — Exigences d’émission (norme IEC CISPR 32:2015 adoptée, deuxième édition, 2015-03, avec exigences propres au Canada) |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CISPR 13:2009+AMD1:2015 CSV | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
CISPR 32:2015 RLV | Electromagnetic compatibility of multimedia equipment - Emission requirements |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.