• IEC PAS 63151:2018

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Vector measurement-based systems (Frequency range of 30 MHz to 6 GHz)

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  31-12-2021

    Language(s):  English

    Published date:  15-01-2018

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviated terms
    5 Overview of the measurement procedure
    6 Measurement system specifications
    7 Protocol for SAR assessment
    8 Uncertainty estimation
    9 Measurement report
    Annex A (normative) - Phantom specifications
    Annex B (normative) - Calibration and characterization
            of dosimetric probes
    Annex C (informative) - Field Reconstruction Techniques
    Annex D (normative) - SAR measurement system
            verification and validation
    Annex E (informative) - Interlaboratory comparisons
    Annex F (normative) - Validation antennas
    Annex G (normative) - Calibration of Reference Antennas
    Annex H (normative) - General considerations on uncertainty
            estimation
    Annex I (normative) - Evaluation of the measurement
            system uncertainty
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC PAS 63151:2018(E) specifies protocols and test procedures for the reproducible measurement of the peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of the head or the body by radio-frequency (RF) transmitting devices, with a defined uncertainty. It provides requirements for systems using vector measurement-based systems. Such systems determine the psSAR by 3D field reconstruction within the volume of interest by specifying the requirements for the measurement system, calibration, uncertainty assessment and validation methods. The protocols and procedures apply for a significant majority of people including children during use of hand-held and body-worn wireless communication devices.
    This PAS is applicable to any wireless communication device intended to be used at a position near the human head or body at distances up to and including 200 mm. This PAS can be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, combined with other RF-transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range is from 30 MHz to 6 GHz.
    The system validation procedures provided within this PAS cover frequencies from 600 MHz to 6 GHz.
    Some specifications (e.g., validation antennas and other procedures or requirements) are not yet defined over the full frequency range within the scope of this document but will be included in a future revision.
    The device categories covered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers, desktop, laptop devices, multi-band, multi-antenna, and push-to-talk devices.

    General Product Information - (Show below) - (Hide below)

    Committee TC 106
    Development Note Stability Date: 2020. (01/2018)
    Document Type Miscellaneous Product
    Publisher International Electrotechnical Committee
    Status Withdrawn

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    IEC 62209-2:2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
    IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
    IEC 62479:2010 Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
    ISO/IEC Guide 98-1:2009 Uncertainty of measurement — Part 1: Introduction to the expression of uncertainty in measurement
    ISO/IEC Guide 43-1:1997 Proficiency testing by interlaboratory comparisons Part 1: Development and operation of proficiency testing schemes
    IEEE 1720-2012 IEEE Recommended Practice for Near-Field Antenna Measurements
    IEEE 1528-2013 REDLINE IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
    IEC TR 62630:2010 Guidance for evaluating exposure from multiple electromagnetic sources
    ECA 2-07 : 1997 EAL STRATEGY TO ACHIEVE COMPARABILITY OF RESULTS IN CALIBRATION AND TESTING
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective