Residual strength of string insulator units of glass or ceramic material for overhead lines after mechanical damage of the dielectric

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

01-01-1984

€20.79
Excluding VAT

Foreword
Preface
Introduction
1. Scope
2. Object
3. Definition of the residual strength of a cap and pin
    insulator
4. Residual strength test
    4.1 Classification
    4.2 Number of test pieces
    4.3 Previous tests
    4.4 Preparation of the test pieces
    4.5 Residual strength test
    4.6 Evaluation of the test results
Appendix A1 - Residual strength of ceramic long rod insulators
         A2 - Previous tests

Applies to string insulator units of the cap and pin type with insulating parts of toughened glass or ceramic material. Note. - The test procedure given in this report is not applicable to ceramic long rod insulators for the reasons given in Appendix A. Annealed glass cap and pin string insulator units are not considered in this report. Has the status of a technical report.

Committee
TC 36
DocumentType
Technical Report
Pages
15
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
NEN 10797 : 1987 Identical
UNE 21163:1988 Identical

UNE-EN 50341-1:2017 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
CSA C1325 : 1999 : R2016 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN 61325:1997 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
BS EN 61467:2008 Insulators for overhead lines. Insulator strings and sets for lines with a nominal voltage greater than 1000 V. AC power arc tests
CEI EN 61325 : 1998 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
VDE 0446-5 : 1996 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR DC SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
DIN EN 61325 : 1996 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
BS EN 61325:1996 Insulators for overhead lines with a nominal voltage above 1000 V. Ceramic or glass insulator units for d.c systems. Definitions, test methods and acceptance criteria
CEI EN 61467 : 2009 INSULATORS FOR OVERHEAD LINES - INSULATOR STRINGS AND SETS FOR LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - AC POWER ARC TESTS
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
IEC 61325:1995 Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for d.c. systems - Definitions, test methods and acceptance criteria
IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
CSA C1325 : 1999 : R2011 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1000 V - CERAMIC OR GLASS INSULATOR UNITS FOR D.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
I.S. EN 61467:2008 INSULATORS FOR OVERHEAD LINES - INSULATOR STRINGS AND SETS FOR LINES WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - AC POWER ARC TESTS
EN 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
EN 61325:1995 Insulators for overhead lines with a nominal voltage above 1 kV - Ceramic or glass insulator units for d.c. systems - Definitions, test methods and acceptance criteria

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.