IEC TR 61010-3-061:1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-061: Conformity verification report for IEC 61010-2-061, Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English
26-02-1999
Foreword
Conformity verification report IEC 61010-2-61
5 Marking and documentation
6 Protection against electric shock
7 Protection against mechanical hazards
8 Mechanical resistance to shock, vibration and impact (AM1 only)
Mechanical resistance to shock and impact (AM2)
9 Equipment temperature limits and protection against the
spread of fire
10 Resistance to heat
11 Resistance to moisture and liquids (AM 1 only)
Protection against hazards from fluids (AM 2)
12 Protection against radiation, including laser sources
and against sonic and ultrasonic pressure
13 Protection against liberated gases, explosion and
implosion
14 Components
15 Protection by interlocks
16 Measuring circuits
Annex K - Routine tests
Table 1 - Documents attached to this report
Table 2 - Test equipment list
Table 3 - List of components relied on for safety
Form A.1 to Form A.29
A technical report for use by test houses and other users. It assists them with determining and recording verification of conformity of the equipment under test with the requirements of IEC 61010-2-061 (1995). If the paper version of the report is ordered, a diskette is provided with fill-in tables for recording the test results. If the report is downloaded directly from the web, it consists of two files: the technical report as a ZIP file and the fill-in tables as a WORD file.
Committee |
TC 66
|
DocumentType |
Technical Report
|
Pages |
62
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
BS IEC 61010-3.061 : 1999 | Identical |
CSA Z15190 : 2005 : R2010 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
ISO 15190:2003 | Medical laboratories Requirements for safety |
BS ISO 15190:2003 | Medical laboratories. Requirements for safety |
CSA Z15190 : 2005 : R2015 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
CSA Z15190 : 2005 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
IEC 61010-2-061:2015 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.