• IEC TR 61010-3-061:1999

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-061: Conformity verification report for IEC 61010-2-061, Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  31-12-2021

    Language(s):  English

    Published date:  26-02-1999

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
          Conformity verification report IEC 61010-2-61
    5 Marking and documentation
    6 Protection against electric shock
    7 Protection against mechanical hazards
    8 Mechanical resistance to shock, vibration and impact (AM1 only)
          Mechanical resistance to shock and impact (AM2)
    9 Equipment temperature limits and protection against the
          spread of fire
    10 Resistance to heat
    11 Resistance to moisture and liquids (AM 1 only)
          Protection against hazards from fluids (AM 2)
    12 Protection against radiation, including laser sources
          and against sonic and ultrasonic pressure
    13 Protection against liberated gases, explosion and
          implosion
    14 Components
    15 Protection by interlocks
    16 Measuring circuits
    Annex K - Routine tests
    Table 1 - Documents attached to this report
    Table 2 - Test equipment list
    Table 3 - List of components relied on for safety
    Form A.1 to Form A.29

    Abstract - (Show below) - (Hide below)

    A technical report for use by test houses and other users. It assists them with determining and recording verification of conformity of the equipment under test with the requirements of IEC 61010-2-061 (1995). If the paper version of the report is ordered, a diskette is provided with fill-in tables for recording the test results. If the report is downloaded directly from the web, it consists of two files: the technical report as a ZIP file and the fill-in tables as a WORD file.

    General Product Information - (Show below) - (Hide below)

    Committee TC 66
    Document Type Technical Report
    Publisher International Electrotechnical Committee
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    CSA Z15190 : 2005 : R2010 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY
    ISO 15190:2003 Medical laboratories Requirements for safety
    BS ISO 15190:2003 Medical laboratories. Requirements for safety
    CSA Z15190 : 2005 : R2015 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY
    CSA Z15190 : 2005 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61010-2-061:2015 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective