FOREWORD
1 Scope
2 Normative references
3 Electromagnetic phenomena
4 The intrinsic screening parameters of short cables
5 Long cables - coupled transmission lines
6 Transfer impedance of a braided wire outer conductor
  or screen
7 Test possibilities
8 Comparison of the frequency response of different
  triaxial test set-ups to measure the transfer impedance
  of cable screens
9 Background of the shielded screening attenuation test
  method (IEC 62153-4-4)
Annex A (normative) - List of symbols
Bibliography

IEC/TR 62153-4-1:2010(E) gives a brief introduction to basic concepts and terms trying to reveal the common features of apparently different test methods. It should assist in correct interpretation of test data, and in the better understanding of screening (or shielding) and related specifications and standards. This second edition cancels and replaces the first edition published in 2007. The significant change is a new clause on the background of the shielded screening attenuation test method.
This publication contains colours which are considered to beuseful for the correct understanding of its contents.

Committee
TC 46
DevelopmentNote
Supersedes IEC 61917. (11/2007) Stability Date: 2013. (10/2012)
DocumentType
Technical Report
Pages
72
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

08/30182556 DC : DRAFT MAY 2008 BS EN 62153-4-11 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-11: ELECTROMAGNETIC COMPATIBILITY (EMC) - COUPLING ATTENUATION OR SCREENING ATTENUATION OF PATCH CORDS/COAXIAL CABLE ASSEMBLIES/PRE-CONNECTORISED CABLES ABSORBING CLAMP METHOD
IEC 62153-4-14:2012 Metallic communication cable test methods - Part 4-14: Electromagnetic compatibility (EMC) - Coupling attenuation of cable assemblies (Field conditions) absorbing clamp method
BS IEC 62153-4-3:2013 Metallic communication cable test methods Electromagnetic compatibility (EMC). Surface transfer impedance. Triaxial method
08/30182560 DC : DRAFT MAY 2008 BS EN 62153-4-12 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-12: ELECTROMAGNETIC COMPATIBILITY (EMC) - COUPLING ATTENUATION OR SCREENING ATTENUATION OF CONNECTING HARDWARE - ABSORBING CLAMP METHOD
IEC 62153-4-3:2013 Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method
11/30247112 DC : 0 BS EN 62153-4-3 ED.2 - METALIC COMMUNICATION CABLE TEST METHODS - PART 4-3: ELECTROMAGNETIC COMPATABILITY (EMC) - SURFACE TARNSFER IMPEDANCE - TRIAXIAL METHOD
08/30182564 DC : DRAFT MAY 2008 BS EN 62153-4-13 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-13: ELECTROMAGNETIC COMPATIBILITY (EMC) - COUPLING ATTENUATION OF LINKS AND CHANNELS (LABORATORY CONDITIONS) ABSORBING CLAMP METHOD
13/30279876 DC : 0 BS EN 62153-4-15 ED.1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-15: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING TRANSFER IMPEDANCE AND SCREENING ATTENUATION - OR COUPLING ATTENUATION WITH TRIAXIAL CELL
13/30292984 DC : 0 BS EN 62153-4-10 ED2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-10: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE SCREENING EFFECTIVENESS OF FEED-THROUGHS AND ELECTROMAGNETIC GASKETS DOUBLE COAXIAL METHOD
13/30283920 DC : 0 BS EN 62153-4-7 ED.2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE TRANSFER IMPEDANCE Z[T] AND THE SCREENING ATTENUATION A[S] OR THE COUPLING ATTENUATION A[C] OF RF-CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ; TUBE

IEC 62153-4-3:2013 Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method
EN 50289-1-6:2002 Communication cables - Specifications for test methods - Part 1-6: Electrical test methods - Electromagnetic performance
IEC 62153-4-4:2015 Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
IEC 60169-1-3:1988 Radio-frequency connectors - Part 1: General requirements and measuring methods - Section Three: Electrical tests and measuring procedures: Screening effectiveness
IEC 61196-1:2005 Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements
IEC 62153-4-5:2006 Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) - Coupling or screening attenuation - Absorbing clamp method
IEC 60096-4-1:1990 Radio-frequency cables. Part 4: Specification for superscreened cables - Section One: General requirements and test methods
IEC 61726:2015 Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.